Measurement range (per bin) |
0 – 130 m3 (0 – 170 yd3) 1 |
Measurement resolution |
0.1 m3 / 0.1 yd3 2 |
Measurable vehicle types |
Standard mounting: conventional open bin on-road truck, truck-trailer, articulated semi-trailer and B-train combinations (including bottom-dump, side-tipper and belt unloaders); road-trains with up to 4 bins; solid-sided rectangular tractor trailers; maximum 3m (10′) wide, 4.25m (14′) high.Extended outrigger: articulated off-highway dump trucks (mine, quarry, underground); maximum 3.5m (11.5′) wide, 5.50m (18′) high Custom mounting: |
Measurable bin capacity |
1.5 – 130.0 m3 (2.0 – 170 yd3) |
Measurable load types |
Flowable solids (particulate bulk materials) including: rock aggregates, gravel, lightweight aggregates, sand, soil, clay, spoil, compost, bark, woodchip, mulch, other garden/landscaping specialty mixes, fertilizer, shredded waste and so on. |
Maximum load particle diameter (average) |
200 mm (8″) for trade certified systems or for rated accuracy |
Typical measurement accuracy |
Better than 1% to limit of resolution |
Vehicle speed (during scanning) |
0.5 – 8.0 kmph (0.3 – 5.0 mph) 3 |
Power requirements |
110 – 240 VAC, 50/60Hz
5 A max @ 115 VAC 2.5 A max @ 230 VAC 4 (24 VDC, 14 A max option) |
Laser class |
Class 1 (eye-safe), Pmax < 5 mW |
Clearance (from ground) |
Standard mounting: 5.0 m (16.4′) minimum Extended outrigger: 6.3 m (20.7′) minimum Custom mounting: application dependent |
Rated operating conditions, certifications
Operating temperature |
Scan head, message board: -30 – 50°C (-22 – 122°F) (-40°C – 50°C (-40°F – 122°F) for heavy duty variant) Operator console, printer: 0 – 50°C (32 – 122°F) |
Relative humidity(non-condensing) |
Scan head, message board: 5 – 93% Operator console, printer, power box: 20 – 80% |
Power box IP rating |
IP54 |
Minimum visibility |
50 m (164’) (dense fog) |
Maximum scan-track gradient |
5 degrees (9%) |
Maximum scan-track camber |
3 degrees (5%) |
Maximum altitude |
2000 m (6,500 ft) above sea level |
Overvoltage category |
II |
Pollution degree |
Scan head, message board: 4 Operator console, printer, power box: 2 |
Type Approvals for trade use |
New Zealand: 1556 (Trading Standards) Australia: 13/1/15 (NMI)) United States: CC 24-001P (NTEP, provisional) |
Certifications |
CE |
1 New Zealand: 85 m3 maximum measurement per bin and 0.5 m3 minimum tradable quantity for trade verified/certified systems as approved by Trading Standards (Pattern Approval Certificate number 1556).
Australia: 35 m3 maximum measurement per tray and 1 m3 minimum tradable quantity for trade verified/certified systems as approved by NMI (Pattern Approval Certificate number 13/1/15).
USA, Canada and International: Load Volume Scanners will be provided as monitoring systems and do not currently have any specific approvals by weights and measures authorities for trade use (where financial transactions take place). However, LVS units perform to the same level of accuracy as trade approved systems operated in New Zealand and Australia.
2 0.05 m3 below 2.5 m3 measured volume for New Zealand only.
3 New Zealand: 6 kmph maximum for trade verified/certified systems as approved by Trading Standards (Pattern Approval Certificate number 1556).
Australia: 6 kmph maximum for trade verified/certified systems as approved by NMI (Pattern Approval Certificate number 13/1/15).
4 Europe: in accordance with CE certification, the following CE certified optional components are approved to be powered from the system power box (5A circuit):
- Thermal POS printer for ticket printing
- Cellular router for internet connectivity when wired internet not available on site.
Wireless (WiFi) Access Point for wireless network connectivity when wired network not available.
In this Article
General specifications
Measurement range (per bin) |
0 – 130 m3 (0 – 170 yd3) 1 |
Measurement resolution |
0.1 m3 / 0.1 yd3 2 |
Measurable vehicle types |
Standard mounting: conventional open bin on-road truck, truck-trailer, articulated semi-trailer and B-train combinations (including bottom-dump, side-tipper and belt unloaders); road-trains with up to 4 bins; solid-sided rectangular tractor trailers; maximum 3m (10′) wide, 4.25m (14′) high.Extended outrigger: articulated off-highway dump trucks (mine, quarry, underground); maximum 3.5m (11.5′) wide, 5.50m (18′) high Custom mounting: |
Measurable bin capacity |
1.5 – 130.0 m3 (2.0 – 170 yd3) |
Measurable load types |
Flowable solids (particulate bulk materials) including: rock aggregates, gravel, lightweight aggregates, sand, soil, clay, spoil, compost, bark, woodchip, mulch, other garden/landscaping specialty mixes, fertilizer, shredded waste and so on. |
Maximum load particle diameter (average) |
200 mm (8″) for trade certified systems or for rated accuracy |
Typical measurement accuracy |
Better than 1% to limit of resolution |
Vehicle speed (during scanning) |
0.5 – 8.0 kmph (0.3 – 5.0 mph) 3 |
Power requirements |
110 – 240 VAC, 50/60Hz
5 A max @ 115 VAC 2.5 A max @ 230 VAC 4 (24 VDC, 14 A max option) |
Laser class |
Class 1 (eye-safe), Pmax < 5 mW |
Clearance (from ground) |
Standard mounting: 5.0 m (16.4′) minimum Extended outrigger: 6.3 m (20.7′) minimum Custom mounting: application dependent |
Rated operating conditions, certifications
Operating temperature |
Scan head, message board: -30 – 50°C (-22 – 122°F) (-40°C – 50°C (-40°F – 122°F) for heavy duty variant) Operator console, printer: 0 – 50°C (32 – 122°F) |
Relative humidity(non-condensing) |
Scan head, message board: 5 – 93% Operator console, printer, power box: 20 – 80% |
Power box IP rating |
IP54 |
Minimum visibility |
50 m (164’) (dense fog) |
Maximum scan-track gradient |
5 degrees (9%) |
Maximum scan-track camber |
3 degrees (5%) |
Maximum altitude |
2000 m (6,500 ft) above sea level |
Overvoltage category |
II |
Pollution degree |
Scan head, message board: 4 Operator console, printer, power box: 2 |
Type Approvals for trade use |
New Zealand: 1556 (Trading Standards) Australia: 13/1/15 (NMI)) United States: CC 24-001P (NTEP, provisional) |
Certifications |
CE |
1 New Zealand: 85 m3 maximum measurement per bin and 0.5 m3 minimum tradable quantity for trade verified/certified systems as approved by Trading Standards (Pattern Approval Certificate number 1556).
Australia: 35 m3 maximum measurement per tray and 1 m3 minimum tradable quantity for trade verified/certified systems as approved by NMI (Pattern Approval Certificate number 13/1/15).
USA, Canada and International: Load Volume Scanners will be provided as monitoring systems and do not currently have any specific approvals by weights and measures authorities for trade use (where financial transactions take place). However, LVS units perform to the same level of accuracy as trade approved systems operated in New Zealand and Australia.
2 0.05 m3 below 2.5 m3 measured volume for New Zealand only.
3 New Zealand: 6 kmph maximum for trade verified/certified systems as approved by Trading Standards (Pattern Approval Certificate number 1556).
Australia: 6 kmph maximum for trade verified/certified systems as approved by NMI (Pattern Approval Certificate number 13/1/15).
4 Europe: in accordance with CE certification, the following CE certified optional components are approved to be powered from the system power box (5A circuit):
- Thermal POS printer for ticket printing
- Cellular router for internet connectivity when wired internet not available on site.
Wireless (WiFi) Access Point for wireless network connectivity when wired network not available.