{"id":15683,"date":"2024-06-10T12:58:06","date_gmt":"2024-06-10T00:58:06","guid":{"rendered":"https:\/\/portal.loadscan.com\/2-configuracion-manual-del-operador-serie-cvs-1-rev3\/"},"modified":"2024-10-18T13:54:58","modified_gmt":"2024-10-18T00:54:58","slug":"2-configuracion-manual-del-operador-serie-cvs-1-rev3","status":"publish","type":"post","link":"https:\/\/portal.loadscan.com\/es\/2-configuracion-manual-del-operador-serie-cvs-1-rev3\/","title":{"rendered":"2 Configuraci\u00f3n &#8211; Manual del Operador &#8211; CVS-1 Serie Rev3"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1331.2px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-margin-top-small:20px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h2 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:28;--minFontSize:28;line-height:1.5;\">2. Configuraci\u00f3n<\/h2><\/div><div class=\"fusion-text fusion-text-1\"><h2>2.1 Con\u00e9ctate al CVS<\/h2>\n<p>El CVS incorpora conectividad de red inal\u00e1mbrica (WiFi) y Ethernet por cable.<br \/>\nLa radio inal\u00e1mbrica puede configurarse para utilizar las bandas de 2,4 GHz o 5 GHz y admite los modos punto de acceso o cliente.  Tambi\u00e9n se puede desactivar. Ethernet por cable proporciona conectividad LAN Gigabit opcional. La conexi\u00f3n inicial puede ser inal\u00e1mbrica o por cable y los ajustes de red se pueden modificar desde la interfaz de usuario CVS.  <\/p>\n<h3>2.1.1 Conexi\u00f3n inal\u00e1mbrica<\/h3>\n<p>Por defecto, CVS est\u00e1 configurado como un punto de acceso inal\u00e1mbrico con los siguientes ajustes:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Frecuencia: <\/strong>2,4 GHz<\/div>\n<div style=\"padding-left: 40px;\"><strong>SSID:<\/strong> LoadScan-CVS<\/div>\n<div style=\"padding-left: 40px;\"><strong>Contrase\u00f1a:<\/strong> 2BAD4FAB4A<\/div>\n<div style=\"padding-left: 40px;\"><strong>CVS URL:<\/strong> https:\/\/172.16.1.1<\/div>\n<p>Con\u00e9ctate al hotspot con cualquier dispositivo con WiFi de 2,4 GHz incorporado y un navegador web. Una vez establecida la conexi\u00f3n inal\u00e1mbrica, la interfaz de usuario CVS puede abrirse en un navegador web en la URL especificada. La configuraci\u00f3n de la red inal\u00e1mbrica puede modificarse en la secci\u00f3n <strong>WiFi<\/strong> de <strong>Configuraci\u00f3n del sistema<\/strong>, accesible desde el men\u00fa de la interfaz de usuario CVS. Con\u00e9ctate a trav\u00e9s de Ethernet por cable para modificar la configuraci\u00f3n inal\u00e1mbrica. No conectes interfaces cableadas e inal\u00e1mbricas en la misma subred de red. <\/p>\n<h3>2.1.2 Conexi\u00f3n Ethernet por cable<\/h3>\n<p>Por defecto, el puerto Ethernet por cable (LAN) de CVS est\u00e1 configurado con una direcci\u00f3n IP est\u00e1tica como se indica a continuaci\u00f3n:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Direcci\u00f3n IP:<\/strong> 192.168.0.1<\/div>\n<div style=\"padding-left: 40px;\"><strong>M\u00e1scara de subred:<\/strong> 255.255.255.0<\/div>\n<div style=\"padding-left: 40px;\"><strong>CVS URL:<\/strong> https:\/\/192.168.0.1<\/div>\n<p>Con\u00e9ctate mediante un cable Ethernet desde cualquier dispositivo con un puerto Ethernet incorporado y un navegador web. Configura la direcci\u00f3n IP de tu dispositivo en otra direcci\u00f3n IP est\u00e1tica de la subred 192.168.0.0. Una vez establecida la conexi\u00f3n de red, se puede abrir la interfaz de usuario CVS en un navegador web en la URL especificada. La configuraci\u00f3n de Ethernet por cable puede modificarse en la secci\u00f3n <strong>Ethernet<\/strong> de <strong>Configuraci\u00f3n del sistema<\/strong>, accesible desde el men\u00fa de la interfaz de usuario CVS. Ten en cuenta que si se configura un <strong>router (pasarela)<\/strong> est\u00e1tico o autom\u00e1tico (DHCP), se utilizar\u00e1 Ethernet por cable para todas las conexiones de red de \u00e1rea amplia (WAN); de lo contrario, se utilizar\u00e1 la conexi\u00f3n inal\u00e1mbrica. No conectes interfaces cableadas e inal\u00e1mbricas en la misma subred de red.  <\/p>\n<h3>2.1.3 Acceder a la interfaz de usuario CVS <\/h3>\n<p>Cuando la interfaz de usuario de CVS se abre en un navegador web por primera vez, se mostrar\u00e1 una p\u00e1gina de inicio de sesi\u00f3n. Inicia sesi\u00f3n con las siguientes credenciales: <\/p>\n<p style=\"padding-left: 40px;\"><strong>Inicio de sesi\u00f3n:<\/strong> admin<\/p>\n<p style=\"padding-left: 40px;\"><strong>Contrase\u00f1a:<\/strong> loadscan<\/p>\n<p>Despu\u00e9s de iniciar sesi\u00f3n como admin, se pueden cambiar las opciones de inicio de sesi\u00f3n y las contrase\u00f1as en la opci\u00f3n  <strong>Usuarios<\/strong>  secci\u00f3n de  <strong>Configuraci\u00f3n del sistema<\/strong>, accesible desde el men\u00fa de la interfaz de usuario CVS.<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\" style=\"--awb-margin-top:40px;\"><h2>2.2 Configuraci\u00f3n del sistema<\/h2>\n<\/div><div class=\"fusion-text fusion-text-3\"><div>Los ajustes de configuraci\u00f3n est\u00e1n disponibles en <strong>Configuraci\u00f3n del sistema<\/strong>, accesible desde el men\u00fa de la interfaz de usuario CVS (se requiere inicio de sesi\u00f3n de administrador).<br \/>\nUtiliza el men\u00fa desplegable de la izquierda para navegar a las diferentes secciones de configuraci\u00f3n. <\/div>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1326\" height=\"750\" title=\"CVS-2.2a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a.png\" alt class=\"img-responsive wp-image-13731\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-200x113.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-400x226.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-600x339.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-800x452.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-1200x679.png 1200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a.png 1326w\" sizes=\"(max-width: 800px) 100vw, 1326px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>Revisa todos los ajustes y modif\u00edcalos para adaptarlos a tu regi\u00f3n, aplicaci\u00f3n y entorno de red.<br \/>\nPara obtener informaci\u00f3n adicional sobre algunos par\u00e1metros de configuraci\u00f3n, pulsa sobre el bot\u00f3n <i class=\"fb-icon-element-1 fb-icon-element fontawesome-icon fa-info-circle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:#006fc4;--awb-font-size:14px;--awb-margin-right:7px;\"><\/i> icono.<\/p>\n<\/div><div class=\"fusion-text fusion-text-5\"><h2>2.3 Configuraci\u00f3n de la medici\u00f3n<\/h2>\n<\/div><div class=\"fusion-text fusion-text-6\"><div>Los ajustes de medici\u00f3n est\u00e1n disponibles en la secci\u00f3n <strong>Medici\u00f3n<\/strong> de la <strong>Configuraci\u00f3n del Sistema<\/strong>.<\/div>\n<h3>2.3.1 Unidades<\/h3>\n<div>Ajusta todas las unidades de medida a los valores apropiados para tu regi\u00f3n y aplicaci\u00f3n.<br \/>\nLas unidades pueden cambiarse en cualquier momento y todas las mediciones actuales e hist\u00f3ricas comunicadas utilizar\u00e1n las unidades actualizadas. <\/div>\n<h3>2.3.2 Sensibilidad<\/h3>\n<p>La sensibilidad controla la respuesta de la medici\u00f3n a niveles muy bajos de material en la cinta. Cuando est\u00e1 ajustada a Alta (por defecto), la medici\u00f3n se activa por el nivel m\u00e1s bajo detectable de material en la cinta. Si la vibraci\u00f3n y el movimiento de la cinta provocan la medici\u00f3n cuando la cinta est\u00e1 vac\u00eda, prueba a cambiar la sensibilidad a Media o Baja. Esto reducir\u00e1 las mediciones no deseadas, pero tambi\u00e9n puede hacer que no se realicen mediciones cuando la cinta est\u00e9 muy poco cargada. El mejor ajuste debe determinarse experimentalmente.    <\/p>\n<h3>2.3.3 Velocidad de la cinta<\/h3>\n<p>Configura el m\u00e9todo de entrada de la velocidad de la cinta y el calibrado seg\u00fan sea necesario. Si hay instalado un sensor de velocidad inductivo:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Fuente de velocidad<\/strong> Codificador<\/div>\n<div style=\"padding-left: 40px;\"><strong>Resoluci\u00f3n del codificador<\/strong> Circunferencia del rodillo de arrastre en mm, medida en 1.3.2 o aj\u00fastala para que la velocidad indicada coincida con la velocidad conocida medida con un tac\u00f3metro manual u otro m\u00e9todo.<\/div>\n<p>Ten en cuenta que la velocidad actual de la cinta se muestra con la m\u00e1xima resoluci\u00f3n posible en la p\u00e1gina Perfil de la cinta, accesible desde el men\u00fa de la interfaz de usuario. Esto permite comparar con precisi\u00f3n la velocidad calibrada de la cinta. Si no se ha instalado un sensor inductivo de velocidad y la velocidad de la cinta es un valor constante conocido: <\/p>\n<div style=\"padding-left: 40px;\"><strong>Fuente de velocidad<\/strong> Velocidad fija<\/div>\n<div style=\"padding-left: 40px;\"><strong>Velocidad fija<\/strong> Velocidad conocida de la cinta en la unidad de medida de velocidad seleccionada.<\/div>\n<p>Ten en cuenta que el valor de velocidad fija se puede actualizar a trav\u00e9s de la API RESTful HTTP. Opcionalmente, establece Utilizar se\u00f1al de control de cinta en marcha en S\u00ed para controlar cu\u00e1ndo la cinta est\u00e1 en marcha con una se\u00f1al de control externa. En este caso, la velocidad de la cinta se forzar\u00e1 a cero cuando la se\u00f1al no est\u00e9 activada. Esto est\u00e1 pensado para utilizarse con un ajuste de velocidad fijo, pero funcionar\u00e1 para cualquier fuente de velocidad. Hay que asignar una entrada de conmutaci\u00f3n digital o una bobina Modbus a la entrada de se\u00f1al de control \u00abCinta en marcha\u00bb (ver <em><strong><span style=\"color: #ff0000;\">2.4.1 Asignar se\u00f1ales de control a entradas<\/span><\/strong><\/em>). Si la velocidad de la cinta est\u00e1 siendo medida por un sistema externo y enviada a CVS por un cliente Modbus TCP o una entrada de bucle de corriente de 4-20 mA (se necesita una caja de E\/S complementaria CVS):<\/p>\n<div style=\"padding-left: 40px;\"><strong>Fuente de velocidad: <\/strong> Entrada de velocidad de la cinta<\/div>\n<p>En este caso, debe asignarse un registro de retenci\u00f3n Modbus o un canal de entrada anal\u00f3gica de E\/S CVS a la entrada de valor de control \u00abVelocidad de la cinta\u00bb (ver <em><strong><span style=\"color: #ff0000;\">2.4 Configuraci\u00f3n de entradas\/salidas<\/span><\/strong><\/em><span style=\"color: #ff0000;\">)<\/span>. Para activar el promedio de velocidad de la cinta, establece el n\u00famero de segundos durante los que se promediar\u00e1 en Periodo de promedio de velocidad. El periodo m\u00e1ximo de promediado es de 600 segundos (10 minutos). Pon cero para desactivar el promedio. Ten en cuenta que promediar durante un largo periodo de tiempo puede provocar un retraso en la respuesta a cambios repentinos, como el arranque\/parada de la cinta o el arranque\/parada del material de carga.<\/p>\n<h3>2.3.4 Caudal<\/h3>\n<p>Para activar el c\u00e1lculo del promedio de caudal m\u00e1sico y volum\u00e9trico, establece el n\u00famero de segundos durante los que se calcular\u00e1 el promedio en <strong>Periodo de c\u00e1lculo del promedio de caudal<\/strong>. El periodo m\u00e1ximo de promediado es de 600 segundos (10 minutos). Pon cero para desactivar el promedio. Ten en cuenta que promediar durante un largo periodo de tiempo puede provocar un retraso en la respuesta a cambios repentinos, como el arranque\/parada de la cinta o el arranque\/parada del material de carga.   <\/p>\n<h3>2.3.5 Altura de carga<\/h3>\n<p>La altura de la carga es una medida de la altura\/profundidad del material de carga sobre la cinta. Establece el <strong>m\u00e9todo Altura de carga<\/strong> en uno de los siguientes: <strong>Altura central<\/strong> es la altura vertical de la carga en el centro de la cinta. La altura <strong>m\u00e1xima<\/strong> es la altura vertical m\u00e1xima de la carga. Este es el punto m\u00e1s profundo de la carga y puede no ocurrir necesariamente en el punto m\u00e1s alto de la superficie superior de la carga.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:700px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"900\" height=\"300\" title=\"MPT_CVS-graph1\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1.png\" alt class=\"img-responsive wp-image-13783\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-200x67.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-400x133.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-600x200.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-800x267.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1.png 900w\" sizes=\"(max-width: 800px) 100vw, 900px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-7\"><p>Para activar el promediado de altura <strong>de<\/strong> carga, establece el n\u00famero de segundos sobre los que promediar en <strong>Periodo de pro<\/strong>mediado <strong>de altura de carga<\/strong>. El periodo de promedio m\u00e1ximo es de 600 segundos (10 minutos). Pon cero para desactivar el promedio. Ten en cuenta que promediar durante un largo periodo de tiempo puede provocar un retraso en la respuesta a cambios repentinos, como el arranque\/parada de la cinta o el arranque\/parada del material de carga.   <\/p>\n<h3>2.3.6 Posici\u00f3n de carga<\/h3>\n<p>La Posici\u00f3n de la carga es una medida de la distribuci\u00f3n del material de carga a trav\u00e9s de la cinta e informa de la posici\u00f3n del centro de masa del material de carga, calculada a partir de la secci\u00f3n transversal de la carga sobre la cinta. La posici\u00f3n de la carga se indica en el intervalo 0 &#8211; 1, donde un valor de 0 corresponde al extremo izquierdo del perfil cero definido y un valor de 1 corresponde al extremo derecho. Un valor de 0,5 corresponde al centro del perfil cero definido. Si los puntos extremos del perfil cero son sim\u00e9tricos respecto a la l\u00ednea central del l\u00e1ser, un valor de 0,5 corresponde tambi\u00e9n al punto situado directamente debajo del l\u00e1ser.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:400px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"900\" height=\"475\" title=\"MPT_CVS-graph3\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3.png\" alt class=\"img-responsive wp-image-13787\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-200x106.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-400x211.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-600x317.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-800x422.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3.png 900w\" sizes=\"(max-width: 800px) 100vw, 900px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-8\"><p>La posici\u00f3n de la carga no se calcular\u00e1 si la altura de la carga es inferior a <strong>la Altura m\u00ednima de la carga<\/strong>. En este caso se informa de un valor de 0,5 (centro de la cinta). Para activar el c\u00e1lculo del promedio de la posici\u00f3n de carga, establece el n\u00famero de segundos durante los que se calcular\u00e1 el promedio en <strong>Periodo de c\u00e1lculo del promedio de la posici\u00f3n de carga<\/strong>. El periodo m\u00e1ximo de promediado es de 600 segundos (10 minutos). Pon cero para desactivar el promedio. Ten en cuenta que promediar durante un largo periodo de tiempo puede retrasar la respuesta a cambios repentinos, como el arranque\/parada de la cinta o el arranque\/parada del material de carga.<\/p>\n<\/div><div class=\"fusion-text fusion-text-9\"><h2>2.4 Configuraci\u00f3n de entrada\/salida<\/h2>\n<\/div><div class=\"fusion-text fusion-text-10\"><p>El CVS proporciona entradas y salidas para la supervisi\u00f3n y el control externos mediante el servidor Modbus TCP integrado o la caja de E\/S opcional CVS con entradas y salidas anal\u00f3gicas de bucle de corriente de 4-20 mA y entradas y salidas digitales de conmutaci\u00f3n. Los valores de medici\u00f3n en vivo, las se\u00f1ales de estado, los valores de control y las se\u00f1ales de control pueden asignarse a registros Modbus o canales de E\/S. Si est\u00e1 instalada la caja de E\/S CVS, el ajuste <strong>Hardware de E\/S<\/strong> de la secci\u00f3n <strong>General<\/strong> de la <strong>Configuraci\u00f3n del sistema<\/strong> debe estar en <strong>CVS E\/S externas<\/strong>. Los ajustes generales de entrada y salida est\u00e1n disponibles en la secci\u00f3n<strong> Entradas\/Salidas<\/strong> de la <strong>configuraci\u00f3n del Sistema<\/strong>. La imagen siguiente muestra s\u00f3lo un ejemplo de configuraci\u00f3n.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"1326\" height=\"1217\" title=\"CVS-2.4a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a.png\" alt class=\"img-responsive wp-image-13735\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-200x184.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-400x367.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-600x551.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-800x734.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-1200x1101.png 1200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a.png 1326w\" sizes=\"(max-width: 800px) 100vw, 1326px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-11\"><h3>2.4.1 Entradas de se\u00f1ales de control<\/h3>\n<p>Los sistemas de control externos pueden suministrar las siguientes se\u00f1ales de control. Se pueden leer desde bobinas Modbus o desde entradas de conmutaci\u00f3n digitales: <strong>Cinta en marcha:<\/strong> Si la <strong>se\u00f1al de control Utilizar cinta en marcha<\/strong> se establece en la secci\u00f3n <strong>Velocidad de la cinta<\/strong> de la Configuraci\u00f3n de <strong>la<\/strong> medici\u00f3n, la velocidad de la cinta se forzar\u00e1 a cero cuando no se establezca esta se\u00f1al. Esto est\u00e1 pensado para su uso con un ajuste de velocidad fija, pero funcionar\u00e1 para cualquier fuente de velocidad. <strong>Restablecer totales:<\/strong> un flanco ascendente o una transici\u00f3n 0 &gt; 1 en esta se\u00f1al restablecer\u00e1 los totales acumulados de volumen\/masa a cero. Para la medici\u00f3n en estado de reposo, tiene el mismo efecto que pulsar el bot\u00f3n Reiniciar del Panel de Control. Si se est\u00e1 ejecutando un trabajo, es lo mismo que reiniciar el trabajo activo en la p\u00e1gina Trabajo activo. Para asignar una se\u00f1al de control a un canal de entrada, pulsa el bot\u00f3n <strong>A\u00f1adir<\/strong> en la secci\u00f3n <strong>Entradas de se\u00f1al de control<\/strong> de <strong>Entradas\/Salidas<\/strong> y selecciona la se\u00f1al de control deseada. Esto crea una nueva fila para la se\u00f1al seleccionada. Haz clic en el \u00e1rea de asignaci\u00f3n de esta fila para seleccionar un canal de entrada disponible. Una se\u00f1al de control s\u00f3lo puede asignarse a un canal de entrada. <strong>Bobinas Modbus:<\/strong> las bobinas deben definirse antes de que puedan seleccionarse como canal de entrada (ver <em><strong><span style=\"color: #ff0000;\">2.5 Configuraci\u00f3n del servidor Modbus TCP<\/span><\/strong><\/em>). <strong>Entradas digitales de conmutaci\u00f3n:<\/strong> Si la se\u00f1al de control no es una entrada de tipo pulso, la casilla <strong>Activo alto<\/strong> puede desmarcarse al a\u00f1adir el canal para invertir la l\u00f3gica de la entrada digital. Esta configuraci\u00f3n se puede editar en cualquier momento haciendo clic en el icono de configuraci\u00f3n (<i class=\"fb-icon-element-2 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) en el canal asignado.<br \/>\nConsulta <a href=\"\"><em><strong><span style=\"color: #ff0000;\">LoadScan CVS-Gu\u00eda de instalaci\u00f3n de E\/S<\/span><\/strong><\/em><\/a> para conocer los requisitos de la se\u00f1al y el cableado.<\/p>\n<\/div><div class=\"fusion-text fusion-text-12\"><h3 id=\"toc_242_Status_signal_outputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.2 Salidas de se\u00f1ales de estado<\/h3>\n<p>Las siguientes se\u00f1ales de estado pueden enviarse a sistemas externos de supervisi\u00f3n y control o controlar directamente el arranque\/parada de la cinta, activar luces indicadoras de estado, etc. Pueden escribirse en entradas discretas Modbus o accionar salidas de conmutaci\u00f3n digitales: <\/p>\n<ul>\n<li><strong>Inactivo:<\/strong> el modo de medici\u00f3n est\u00e1 operativo, pero no hay ning\u00fan trabajo activo (s\u00f3lo medici\u00f3n no asignada).<\/li>\n<li><strong>Trabajo activo:<\/strong> hay un trabajo en marcha.<br \/>\nEsta se\u00f1al puede utilizarse, por ejemplo, para poner en marcha la cinta autom\u00e1ticamente cuando se inicia un trabajo y pararla cuando se detiene. <\/li>\n<li><strong>Objetivo de trabajo alcanzado:<\/strong> se ha alcanzado el volumen\/peso objetivo para el trabajo activo y el trabajo sigue en marcha.<br \/>\nEsta se\u00f1al puede utilizarse, por ejemplo, para controlar un indicador visual que avise al operario de que el trabajo est\u00e1 listo para detenerse manualmente. <\/li>\n<li><strong>Cinta negra:<\/strong> la cinta est\u00e1 en marcha (velocidad de la cinta superior a cero), pero no hay material en la cinta.<\/li>\n<li><strong>Cinta parada:<\/strong> la velocidad de la cinta es cero.<\/li>\n<li><strong>Advertencia:<\/strong> est\u00e1 activa una condici\u00f3n de error no fatal que requiere la intervenci\u00f3n del operador.<\/li>\n<li><strong>Error:<\/strong> est\u00e1 activa una condici\u00f3n de error fatal que requiere la intervenci\u00f3n del operador (medici\u00f3n detenida).<\/li>\n<\/ul>\n<p>Para asignar una se\u00f1al de estado a un canal de salida, haz clic en el bot\u00f3n <strong>A\u00f1adir<\/strong> de la secci\u00f3n <strong>Salidas de estado<\/strong> de <strong>Entradas\/Salidas<\/strong>y selecciona la se\u00f1al de estado deseada. Esto crea una nueva fila para la se\u00f1al seleccionada. Haz clic en el \u00e1rea de asignaci\u00f3n de esta fila para seleccionar un canal de salida disponible. Una se\u00f1al de estado puede asignarse a varios canales de salida. Tambi\u00e9n se pueden asignar varias se\u00f1ales de estado a un canal de salida. En este caso, una salida estar\u00e1 activa cuando se active cualquiera de las se\u00f1ales de estado asignadas. Entradas discretas <strong>Modbus:<\/strong> las entradas discretas deben crearse antes de que puedan seleccionarse como canal de salida (ver <em><strong><span style=\"color: #ff0000;\">2.5 Configuraci\u00f3n del servidor Modbus TCP<\/span><\/strong><\/em>). <strong>Salidas digitales de conmutaci\u00f3n:<\/strong> La casilla Activo alto puede desmarcarse al a\u00f1adir el canal para invertir la l\u00f3gica de la salida digital. Esta configuraci\u00f3n se puede editar en cualquier momento haciendo clic en el icono de configuraci\u00f3n (<i class=\"fb-icon-element-3 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) en el canal asignado.<br \/>\nConsulta <a href=\"\"><em><strong><span style=\"color: #ff0000;\">LoadScan CVS-Gu\u00eda de instalaci\u00f3n de E\/S<\/span><\/strong><\/em><\/a> para conocer los requisitos de la se\u00f1al y el cableado. <\/p>\n<h3 id=\"toc_243_Control_value_inputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.3 Entradas de valores de control<\/h3>\n<p>Los siguientes valores de control pueden ser suministrados por sistemas de control externos. Se pueden leer desde registros de retenci\u00f3n Modbus o entradas anal\u00f3gicas de bucle de corriente de 4-20 mA: <\/p>\n<ul>\n<li>Velocidad de la cinta<strong>:<\/strong> Si la fuente de velocidad est\u00e1 ajustada a Entrada de velocidad de la cinta en la secci\u00f3n Velocidad de la cinta de la Configuraci\u00f3n de la medici\u00f3n, este valor ajusta la velocidad de la cinta.<\/li>\n<\/ul>\n<p>Para asignar un valor de control a un canal de entrada, haz clic en el bot\u00f3n A\u00f1adir de la secci\u00f3n Entradas de valores de control de Entradas\/Salidas y selecciona el valor de control deseado. Esto crea una nueva fila para el valor seleccionado. Haz clic en el \u00e1rea de asignaci\u00f3n de esta fila para seleccionar un canal de entrada disponible. Un valor de control s\u00f3lo puede asignarse a una salida. <strong>Registros<\/strong> de retenci\u00f3n <strong>Modbus: los<\/strong> registros de retenci\u00f3n deben crearse antes de que puedan seleccionarse como canal de entrada (ver <em><strong><span style=\"color: #ff0000;\">2.5 Configuraci\u00f3n del servidor Modbus TCP<\/span><\/strong><\/em>). <strong>Entradas anal\u00f3gicas:<\/strong> los valores de control correspondientes a los puntos finales de 4 mA y 20 mA deben especificarse en el momento de a\u00f1adir el canal y pueden editarse en cualquier momento haciendo clic en el icono de configuraci\u00f3n (<i class=\"fb-icon-element-4 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) en el canal asignado. Consulta <span style=\"color: #ff0000;\"><em><strong><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/6-guia-de-instalacion-de-cvs-i-o-manual-del-operador-serie-cvs-1-rev3\/\">LoadScan CVS-Gu\u00eda de instalaci\u00f3n de E\/S<\/a><\/strong><\/em><\/span> para conocer los requisitos y el cableado de la se\u00f1al de entrada anal\u00f3gica. <\/p>\n<h3 id=\"toc_244_Measurement_value_outputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.4 Salidas de valores de medici\u00f3n<\/h3>\n<p>Los siguientes valores de medici\u00f3n pueden enviarse a sistemas externos de supervisi\u00f3n y control. Se pueden escribir en registros de entrada Modbus o en salidas anal\u00f3gicas de bucle de corriente de 4-20 mA: <\/p>\n<ul>\n<li><strong>Volumen acumulado:<\/strong> el volumen total actual<\/li>\n<li><strong>Masa acumulada:<\/strong> el peso total actual<\/li>\n<li><strong>Caudal volum\u00e9trico:<\/strong> el caudal volum\u00e9trico actual<\/li>\n<li><strong>Caudal m\u00e1sico:<\/strong> el caudal m\u00e1sico actual<\/li>\n<li><strong>Velocidad de la<\/strong> cinta<strong>:<\/strong> velocidad actual de la cinta<\/li>\n<li>Altura de carga<strong>:<\/strong> la altura de carga actual<\/li>\n<li><strong>Posici\u00f3n de carga:<\/strong> posici\u00f3n actual de la carga<\/li>\n<\/ul>\n<p>Para asignar un valor de medida a un canal de salida, pulsa el bot\u00f3n <strong>A\u00f1adir<\/strong> en la secci\u00f3n <strong>de salidas de medida<\/strong> de <strong>Entradas\/Salidas<\/strong>y selecciona la medida deseada. Esto crea una nueva fila para la medici\u00f3n seleccionada. Haz clic en el \u00e1rea de asignaci\u00f3n de esta fila para seleccionar un canal de salida disponible. Un valor de medida puede emitirse a varios canales de salida, pero un \u00fanico canal de salida s\u00f3lo puede asignarse a una medida. <strong>Registros de entrada Modbus:<\/strong> los registros de entrada deben crearse antes de que puedan seleccionarse como canal de salida (v\u00e9ase 2.5 Configuraci\u00f3n del servidor Modbus TCP). <strong>Salidas anal\u00f3gicas:<\/strong> los valores de control correspondientes a los puntos finales de 4 mA y 20 mA deben especificarse en el momento de a\u00f1adir el canal y pueden editarse en cualquier momento haciendo clic en el icono de configuraci\u00f3n (<i class=\"fb-icon-element-5 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) en el canal asignado.<br \/>\nConsulta <em><strong><span style=\"\"><a style=\"\" href=\"\">LoadScan CVS-Gu\u00eda de instalaci\u00f3n de E\/S<\/a><\/span> <\/strong><\/em>para conocer los requisitos y el cableado de la se\u00f1al de entrada anal\u00f3gica.<\/p>\n<\/div><div class=\"fusion-text fusion-text-13\"><h2>2.5 Configuraci\u00f3n del servidor Modbus TCP<\/h2>\n<\/div><div class=\"fusion-text fusion-text-14\"><p>Los valores de medici\u00f3n en vivo, las se\u00f1ales de estado, los valores de control y las se\u00f1ales de control pueden asignarse a registros Modbus. Los ajustes del <strong>Servidor<\/strong> Modbus TCP est\u00e1n disponibles en la secci\u00f3n <strong>Servidor Modbus TCP<\/strong> de la <strong>Configuraci\u00f3n del sistema<\/strong>. Este documento asume que el lector est\u00e1 familiarizado con Modbus TCP. La imagen siguiente muestra s\u00f3lo un ejemplo de configuraci\u00f3n.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"1103\" height=\"1001\" title=\"CVS-2.5a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a.png\" alt class=\"img-responsive wp-image-13739\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-200x182.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-400x363.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-600x545.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-800x726.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a.png 1103w\" sizes=\"(max-width: 800px) 100vw, 1103px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-15\"><p>La configuraci\u00f3n Modbus es muy flexible. El CVS no tiene una tabla de registros fija. Los registros Modbus pueden a\u00f1adirse y eliminarse seg\u00fan sea necesario. Las direcciones de los registros tambi\u00e9n se pueden configurar como se desee y hay disponibles m\u00faltiples formatos de datos. El servidor Modbus TCP debe activarse con el bot\u00f3n <strong>Activar servidor Modbus<\/strong> y puede desactivarse en cualquier momento sin perder la configuraci\u00f3n existente. Una vez definidos los registros Modbus, se pueden utilizar como canales de entrada o salida y asignarlos a diferentes valores o se\u00f1ales de medida o control (ver <em><strong><span style=\"color: #ff0000;\">2.4 Configuraci\u00f3n de Entradas\/Salidas<\/span><\/strong><\/em>). Se pueden a\u00f1adir los siguientes tipos de registros Modbus:   <\/p>\n<ul>\n<li><strong>Bobinas:<\/strong> son entradas discretas CVS (salidas del cliente remoto Modbus TCP) y se pueden asignar a entradas de se\u00f1ales de control.<\/li>\n<li><strong>Entradas discretas:<\/strong> son salidas discretas CVS (entradas al cliente remoto Modbus TCP) y se pueden asignar a se\u00f1ales de estado.<\/li>\n<li><strong>Registros de retenci\u00f3n:<\/strong> son entradas de valor al CVS (salidas del cliente remoto Modbus TCP) y pueden asignarse a valores de control.<br \/>\nHay disponibles m\u00faltiples formatos de datos, y opcionalmente se puede aplicar un divisor al valor le\u00eddo de un registro de retenci\u00f3n. <\/li>\n<li><strong>Registros de entrada:<\/strong> son salidas de CVS (entradas al cliente remoto Modbus TCP) y se pueden asignar a valores de medici\u00f3n.<br \/>\nHay varios formatos de datos disponibles, y opcionalmente se puede aplicar un multiplicador al valor antes de escribirlo en un registro de entrada. <\/li>\n<\/ul>\n<p>Para a\u00f1adir un registro Modbus, haz clic en el bot\u00f3n <strong>A\u00f1adir<\/strong> del tipo requerido e introduce los detalles solicitados en el cuadro de di\u00e1logo emergente. Una vez creados los objetos Modbus, aparecen autom\u00e1ticamente en la secci\u00f3n <strong>Entradas\/Salidas<\/strong> de la <strong>Configuraci\u00f3n del sistema<\/strong>, con la asignaci\u00f3n de se\u00f1al o valor seleccionada. Un registro Modbus se puede reasignar a una se\u00f1al o valor diferente o eliminar la asignaci\u00f3n. Eliminar la asignaci\u00f3n en la configuraci\u00f3n de Entradas\/Salidas borra la asignaci\u00f3n, pero no elimina el registro Modbus de la configuraci\u00f3n del Servidor Modbus TCP. Puede eliminarse de la configuraci\u00f3n del Servidor TCP Modbus o reasignarse en la configuraci\u00f3n de Entradas\/Salidas.<\/p>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>El CVS incorpora conectividad de red inal\u00e1mbrica (WiFi) y Ethernet por cable.<br \/>\nLa radio inal\u00e1mbrica puede configurarse para utilizar las bandas de 2,4 GHz o 5 GHz y admite los modos punto de acceso o cliente. <\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[192,193,187,190],"tags":[],"class_list":["post-15683","post","type-post","status-publish","format-standard","hentry","category-escaner-de-volumen-del-transportador","category-guia-del-usuario","category-instalacion-y-configuracion-de-cvs","category-manual-del-operador-cvs"],"_links":{"self":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts\/15683","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/comments?post=15683"}],"version-history":[{"count":0,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts\/15683\/revisions"}],"wp:attachment":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/media?parent=15683"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/categories?post=15683"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/tags?post=15683"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}