{"id":17845,"date":"2024-06-21T08:35:05","date_gmt":"2024-06-20T20:35:05","guid":{"rendered":"https:\/\/portal.loadscan.com\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-4\/"},"modified":"2026-02-03T16:55:13","modified_gmt":"2026-02-03T03:55:13","slug":"escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-4","status":"publish","type":"post","link":"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-4\/","title":{"rendered":"Esc\u00e1ner de volumen de carga &#8211; Gu\u00eda de mantenimiento del software &#8211; Secci\u00f3n 4"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1331.2px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h2>Section 4<\/h2>\n<p><em>Other sections in this Guide can be accessed from the bottom of this page.<\/em><\/p>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:20px;margin-bottom:40px;width:100%;\"><div class=\"fusion-separator-border sep-single sep-solid\" style=\"--awb-height:20px;--awb-amount:20px;--awb-sep-color:var(--awb-color7);border-color:var(--awb-color7);border-top-width:2px;\"><\/div><\/div><div class=\"fusion-text fusion-text-2\"><p>This document describes functionality built into LVS-3.0 series software for access to:<\/p>\n<ul>\n<li>system settings<\/li>\n<li>hardware configuration<\/li>\n<li>testing, diagnostic and configuration utilities.<\/li>\n<\/ul>\n<p>This document has been updated for LVS software version 3.0-638. Minor differences will be present in older versions.<\/p>\n<\/div><div class=\"fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-0 fusion_builder_column_inner_1_6 1_6 fusion-flex-column fusion-flex-align-self-stretch\" style=\"--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:#e2e2e2;--awb-bg-color-hover:#e2e2e2;--awb-bg-size:cover;--awb-width-large:16.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:0%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:0%;--awb-width-medium:16.666666666667%;--awb-order-medium:0;--awb-spacing-right-medium:0%;--awb-spacing-left-medium:0%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><i class=\"fb-icon-element-1 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-iconcolor-hover:var(--awb-color7);--awb-font-size:52px;--awb-margin-top:5px;--awb-margin-bottom:5px;\"><\/i><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-1 fusion_builder_column_inner_5_6 5_6 fusion-flex-column fusion-flex-align-self-stretch\" style=\"--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:#e2e2e2;--awb-bg-color-hover:#e2e2e2;--awb-bg-size:cover;--awb-width-large:83.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:0%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:0%;--awb-width-medium:83.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:0%;--awb-spacing-left-medium:0%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><div class=\"fusion-text fusion-text-3\" style=\"--awb-line-height:1;\"><p><strong>This document is not for distribution to Load Volume Scanner (LVS) end-users.<\/strong><\/p>\n<\/div><\/div><\/div><\/div><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-margin-top-small:20px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h2 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:28;--minFontSize:28;line-height:1.5;\">Custom function settings<\/h2><\/div><div class=\"fusion-text fusion-text-4\"><p>Custom functions are special functionality built into the LVS software but disabled by default.<\/p>\n<p>Specific custom functions can be activated on LVS systems as required. Some custom functions are sold as chargeable \u2018add-ons\u2019.<\/p>\n<p>Activated custom settings can be edited from the user-accessible Custom Settings dialog (Settings &gt; Custom).<\/p>\n<p>New custom functionality and associated settings can only be activated (added) by Loadscan (manufacturing-level access required).<\/p>\n<p>This section lists all custom function settings that can be added and edited from the system maintenance screen (see <em><strong><span style=\"color: #ff0000;\">Edit configuration settings<\/span><\/strong><\/em>). It is grouped by related functionality.<\/p>\n<p>This listing is intended as a quick reference only. Refer to user level documentation for specific custom functions for details of related settings values.<\/p>\n<\/div><div class=\"fusion-reading-box-container reading-box-container-1\" style=\"--awb-title-color:#333333;--awb-margin-top:20px;--awb-margin-bottom:31px;\"><div class=\"reading-box\" style=\"background-color:#fff4dd;border-width:1px;border-color:#f6f6f6;border-left-width:3px;border-left-color:var(--primary_color);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>Custom settings default to blank when activated (added).<\/p>\n<p>Where a default value is specified below, this is the value used if the parameter is activated but left blank.<\/p>\n<p>Where default values are not specified, a blank value is invalid.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-text fusion-text-5\"><h3>LoadTrak<\/h3>\n<p>LoadTrak\u2122 is an add-on product for the LVS system. LoadTrak in-cab consoles provide LVS remote data entry and reporting functionality for truck drivers. Refer to <em><strong><span style=\"color: #ff0000;\">LoadTrak User Guide<\/span><\/strong><\/em> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadTrakEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Built-in LoadTrak web server enabled. This is required for the LoadTrak system to function.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">LoadTrak web server disabled.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-6\"><h3>Volume Correction<\/h3>\n<p>The Volume correction function applies a \u2018compaction factor\u2019 adjustment to the measured volume to account for self-compaction (compression of the load under its own weight).<\/p>\n<p>Refer to the support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-funcion-de-correccion-de-volumen-v1\/\"><em><strong>Loadscan LVS \u2013 Volume Correction Function<\/strong><\/em><\/a><\/span> for details.<\/p>\n<p>Volume Correction was previously known as Compaction Factor Adjustment (CFA).<\/p>\n<\/div><div class=\"fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-2 fusion_builder_column_inner_1_6 1_6 fusion-flex-column fusion-flex-align-self-stretch\" style=\"--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:#e2e2e2;--awb-bg-color-hover:#e2e2e2;--awb-bg-size:cover;--awb-width-large:16.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:0%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:0%;--awb-width-medium:16.666666666667%;--awb-order-medium:0;--awb-spacing-right-medium:0%;--awb-spacing-left-medium:0%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><i class=\"fb-icon-element-2 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-iconcolor-hover:var(--awb-color7);--awb-font-size:52px;--awb-margin-top:5px;--awb-margin-bottom:5px;\"><\/i><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-3 fusion_builder_column_inner_5_6 5_6 fusion-flex-column fusion-flex-align-self-stretch\" style=\"--awb-padding-top:20px;--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:#e2e2e2;--awb-bg-color-hover:#e2e2e2;--awb-bg-size:cover;--awb-width-large:83.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:0%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:0%;--awb-width-medium:83.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:0%;--awb-spacing-left-medium:0%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><div class=\"fusion-text fusion-text-7\" style=\"--awb-line-height:1;\"><p><strong>These settings are ignored on trade certified LVS systems.<\/strong><\/p>\n<\/div><\/div><\/div><\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">VolumeCorrection<br \/>\nEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Volume correction function enabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Volume correction function disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">VolumeCorrection<br \/>\nReportFactor<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Report the applied compaction factor percentage for each scan in a \u2018Compaction Factor\u2019 load detail field.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report applied compaction factors.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">VolumeCorrection ReportRawTotal<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Report the raw measured volume total (before volume correction) for each scan in a \u2018Raw Total\u2019 load detail field.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report raw measured volume totals.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">CompactionFactor%<\/td>\n<td align=\"left\">[Various]<\/td>\n<td align=\"left\">Optionally species a fixed compaction factor percentage instead of using material specific values.<\/p>\n<p>Also required for backwards compatibility. Refer to the support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/ajuste-del-factor-de-compactacion-v3-loadscan-lvs\/\"><em><strong>Loadscan LVS \u2013 Compaction Factor Adjustment (pre-v3.0-619)<\/strong><\/em><\/a><\/span>.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">Use material specific compaction factors.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-8\"><h3>Reference scans<\/h3>\n<p>Custom settings related to empty scan reporting and capacity computation.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">ShowCapacity<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Display estimated bin capacity in vehicle records on the Vehicle Database screen and on reference scan report tickets if printed.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report estimated bin capacity.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">PrintDbaseScanReport<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Print a reference scan report ticket for every reference scan.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not print reference scan report tickets.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">HighSideCapAdjust<\/td>\n<td align=\"left\">0-100<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">(default 50)<\/span><\/td>\n<td align=\"left\">For bins with an average side height on one side more than 300mm higher than the other, the capacity computation can be adjusted to account for how bins are loaded (typical load profile).<\/p>\n<p>&nbsp;<\/p>\n<p>Refer to knowledgebase document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-estimacion-de-la-capacidad-del-lado-alto\/\"><strong><em>Loadscan LVS \u2013 High Side Capacity Computation<\/em><\/strong><\/a><\/span> for details.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">RefScanExpiry<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">OverrideMonths<\/span><\/td>\n<td align=\"left\">0-100<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">(default 0)<\/span><\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-3 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Overrides the reference scan expiry period for the configured region with a custom period in months.<\/p>\n<p>&nbsp;<\/p>\n<p>A value of zero disables reference scan expiry. In this case and no \u2018Reference Scan Expired\u2019 warnings are reported.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-9\"><h3>Weight estimate function<\/h3>\n<p>Weight estimation computes an estimated weight for each bin load, based on supplied product density value(s).<\/p>\n<p>Refer to the support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/load-volume-scanner-weight-estimate-function-v3\/\"><em><strong>Loadscan LVS \u2013 Weight Estimate Function<\/strong><\/em><\/a><\/span> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">WeightEstimateEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-4 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Weight estimate function enabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Weight estimate function disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">WeightEstimateShow<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">DensityFactor<\/span><\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Report the applied density value for each scan in a \u2018Density\u2019 load detail field.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report applied density values.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">WeightEstimate<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">MessageBoardDisplay<\/span><\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-5 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Display weight estimate as the primary measurement on the LED message board load report instead of volume. This provides immediate weight information to truck drivers.<\/p>\n<p>Other load report outputs and saved records are not affected.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Display standard load report on the LED message board.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">WeightEstimate<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">DensityFactor<\/span><\/td>\n<td align=\"left\">[Various]<\/td>\n<td align=\"left\">Optionally specifies a fixed density value instead of using material specific values.<\/p>\n<p>&nbsp;<\/p>\n<p>Also required for backwards compatibility. Refer to the support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-funcion-de-estimacion-de-peso-v3\/\"><em><strong>Loadscan LVS \u2013 Weight Estimate Function (pre-v3.0-619)<\/strong><\/em><\/a><\/span>.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">Use material specific density values.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-10\"><h3>LoadSync API<\/h3>\n<p>LoadSync API\u2122 is a JSON web API that allows measurement records to be retrieved from the LVS. Refer to <em><strong><span style=\"color: #ff0000;\">LoadSync API User Guide<\/span><\/strong><\/em> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadSyncAPIEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">LoadSync API enabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">LoadSync API disabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadSyncAPIPassword<\/td>\n<td align=\"left\">[Text string]<\/td>\n<td align=\"left\">Password (token) for API access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-11\"><h3>LoadSync SQL<\/h3>\n<p>LoadSync SQL\u2122 is an SQL database connectivity add-on for the LVS which pushes new measurement records to a remote database within the corporate network.<\/p>\n<p>Refer to <em><strong><span style=\"color: #ff0000;\">LoadSync SQL User Guide<\/span><\/strong><\/em> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadSyncRemoteEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">LoadSync SQL enabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">LoadSync SQL disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\">LoadSyncRemoteType<\/td>\n<td align=\"left\">sqlsrv<\/td>\n<td align=\"left\">Remote database type is Microsoft SQL Server<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">mysql<\/td>\n<td align=\"left\">Remote database type is MySQL<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">oci<\/td>\n<td align=\"left\">Remote database type is Oracle<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">pgsql<\/td>\n<td align=\"left\">Remote database type is PostgreSQL<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadSyncRemoteServer<\/td>\n<td align=\"left\">[Various]<\/td>\n<td align=\"left\">IP address or network name and port for remote database. Format is dependent on database type.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadSyncRemoteName<\/td>\n<td align=\"left\">[Various]<\/td>\n<td align=\"left\">Name of the remote database. Format is dependent on database type.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadsyncRemoteUser<\/td>\n<td align=\"left\">[Text string]<\/td>\n<td align=\"left\">Login name for connection to the remote database<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadSyncRemote<\/p>\n<p>Password<\/td>\n<td align=\"left\">[Text string]<\/td>\n<td align=\"left\">Login password for connection to the remote database<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">LoadsyncRemoteVersion<\/td>\n<td align=\"left\">1, 2 (default)<\/td>\n<td align=\"left\">Remote database table version (v1 is deprecated).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-12\"><h3>Load status reporting (mining features)<\/h3>\n<p>Special functions for mining applications. These settings are automatically enabled on MPS systems (\u2018MiningMode\u2019 system setting set to TRUE) but can be selectively enabled on LVS systems. See support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-informe-de-estado-de-carga-v2\/\"><strong><em>Loadscan LVS \u2013 Load Status Reporting Guide<\/em><\/strong><\/a><\/span> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadStatusReporting<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">Enable<\/span><\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Load status reporting enabled.<\/p>\n<p><strong>Note:<\/strong> The measurement records log file format is forced to v4 if not already. This may affect older systems generating v3 format log files. Refer to support document <strong><span style=\"color: #ff0000;\"><em>Loadscan LVS \u2013 Log File Formats<\/em><\/span><\/strong> for details.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Load status reporting disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadStatusReporting<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">LeftRightRatio<\/span><\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Report left\/right load distribution ratio in a \u2018Left\/Right (%)\u2019 load detail field. Requires \u2018LoadStatusReportingEnable\u2019 set to TRUE.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report left\/right load distribution ratio. Load distribution thresholds can still be applied.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">LoadStatusReporting<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">FrontRearRatio<\/span><\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Report front\/rear load distribution ratio in a \u2018Front\/Rear (%)\u2019 load detail field. Requires \u2018LoadStatusReportingEnable\u2019 set to TRUE.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not report front\/rear load distribution ratio. Load distribution thresholds can still be applied.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-13\"><h3>Debris monitoring<\/h3>\n<p>Special functions developed for the North American \u2018debris monitoring\u2019 industry which performs disaster recovery operations, such as clean up after major storms.<\/p>\n<p>These functions are intended as a set for debris monitoring applications but can be enabled individually for other applications.<\/p>\n<p>Refer to the support document <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-control-de-escombros\/\"><strong><em>Loadscan LVS \u2013 Debris Monitoring<\/em><\/strong><\/a><\/span> for details.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">EnableBoomFilter<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-6 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Enable \u2018boom filter\u2019 to remove grapple boom from scan profile and allow scanning of grapple trucks where the grapple boom extends over the top of the bin.<\/p>\n<p>&nbsp;<\/p>\n<p>Only suitable for applications where accuracy is not crucial.<\/p>\n<p>This filter cannot work in all cases and accuracy of measurement is lower for grapple trucks.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Boom filter disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">WetBlanketFilter<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-7 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Enable \u2018wet blanket filter\u2019.<\/p>\n<p>&nbsp;<\/p>\n<p>This is a load profile smoothing filter with a similar effect to draping a wet blanket over the load.<\/p>\n<p>Effectively removes gaps in load where scanners can see through branches etc by smoothing in upward (positive) direction only.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Wet blanket filter disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">CustomColumns<\/td>\n<td align=\"left\">[various]<\/td>\n<td align=\"left\">Comma-separated list of pre-defined custom load details to report and record as extra columns in measurement records.<\/p>\n<p>&nbsp;<\/p>\n<p>Current options are:<\/p>\n<ul>\n<li>Utilization: load as a percentage of estimated bin capacity.<\/li>\n<li>Capacity: estimated bin capacity<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">No custom load details enabled.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-14\"><p><strong>Note:<\/strong> DisableIVP and ShowCapacity custom functions should also be enabled for debris monitoring applications.<\/p>\n<\/div><div class=\"fusion-reading-box-container reading-box-container-2\" style=\"--awb-title-color:#333333;--awb-margin-top:20px;--awb-margin-bottom:31px;\"><div class=\"reading-box\" style=\"background-color:#fff4dd;border-width:1px;border-color:#f6f6f6;border-left-width:3px;border-left-color:var(--primary_color);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>For LVS systems with Compaction Factor Adjustment (CFA) enabled, utilization and capacity are based on raw unadjusted volume.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-text fusion-text-15\"><h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 24; line-height: 1.4; --minfontsize: 24;\" data-fontsize=\"24\" data-lineheight=\"33.6px\">2-Scan measurement<\/h3>\n<p>Extra settings for fine-grained control over 2-scan measurement behaviour. These settings only apply when 2-scan measurement is enabled in user settings.<\/p>\n<p>Enable these settings only where default values do not work well for the application.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">IDOnly2ScanEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Deprecated custom function that allows RFID tags to be registered to &#8216;ID-only&#8217; vehicle records without corresponding reference scans.<\/p>\n<p>Trucks fitted with these tags automatically use 2-scan measurement mode, without manual vehicle identification required.<\/p>\n<p>See LVS knowledgebase document <strong><span style=\"color: #ff0000;\"><em>Automatic 2-scan measurements<\/em><\/span><\/strong> for details.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">ID-only vehicle records not enabled.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">2ScanReturnTimeout<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">Mins<\/span><\/td>\n<td align=\"left\">10-1000<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">(default 360)<\/span><\/td>\n<td align=\"left\">Maximum time in minutes between first and second scan for 2-scan measurement. Default value of 360 is equivalent to 6 hours.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">2ScanRetryTimeoutMins<\/td>\n<td align=\"left\">1-100<br \/>\n<span style=\"font-family: inherit; font-size: inherit;\">(default 10)<\/span><\/td>\n<td align=\"left\">Maximum time in minutes after second scan of 2-scan measurement that second scan can be repeated.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">Force2Scan<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">A 2-scan measurement is initiated without user confirmation when a manually entered vehicle ID is not found in the vehicle database.<\/p>\n<p>This function should only be used where the ID is scanned from a barcode\/QR code and mistakes cannot occur.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">2-scan measurements must be user-initiated for manually entered vehicle IDs.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-16\"><h3>Backwards compatibility<\/h3>\n<p>These settings allow deprecated functionality to be enabled on updated LVS systems.<\/p>\n<p>Backwards compatibility settings should only be activated where the users were previously using the functionality. They should not be used to enable deprecated functionality on new LVS installations.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">OverViewAPIEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">HTTP RESTful API (FileSyncAPI) enabled for OverView reporting software access to measurement records and other user data.<\/p>\n<p>OverView software is now deprecated and LVS users running this software should be encouraged to move to the MyScanner cloud service.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">OverView connectivity to LVS user data disabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">FileSharingEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Local network file-sharing access to LVS user data folders enabled.<\/p>\n<p>File-sharing connections require remote computers to connect as \u2018Guest\u2019 user (with no password by default).<\/p>\n<p>When enabled, a CHANGE NETWORK PASSWORD button is visible in the Password Settings dialog (Settings &gt; Passwords).<\/p>\n<p>Optionally set a password for network access to shared folders on the operator console.<\/p>\n<p>When a password is set, remote network access to shared folders requires connecting as \u201cGuest\u201d user with the password as set.<\/p>\n<p>Set blank password (default) to allow network access without a password.<\/p>\n<p>Note that local network and\/or Microsoft Windows settings may restrict shared folder access without a password. File-sharing is older technology that is becoming increasingly hard to support on secure modern networks.<\/p>\n<p>This setting should only be enabled where the LVS user was previously using file-share access to LVS user data for functionality that is not supported by other methods.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Local network file-sharing connections to LVS user data folders disabled.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-17\"><h3>Manual tracking-only<\/h3>\n<p>Only enable the following settings when the LVS is in Tracking-only mode.<\/p>\n<p>When manual tracking-only is enabled, tracking-only records can be created using the NEW button on the Main screen.<\/p>\n<p>When the NEW button is pushed the system prompts for a single vehicle ID if the MaxBins system setting is 1. If MaxBins is greater than 1, the system prompts for the vehicle type and requests the corresponding number of vehicle\/bin IDs.<\/p>\n<p>Manual tracking-only can be enabled on a tracking-only system with tag reader\/LPR hardware installed but is primarily intended for creating a stand-alone operator console that will only be used for manual entry.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">ManualTrackingEnable<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Enable manual entry of tracking-only records using the NEW button on the Main screen.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Tracking-only records cannot be entered manually.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">ManualTrackingAllowUnregID<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Manual tracking-only records can be created for vehicle IDs that are not found in the vehicle database. The user is prompted to confirm when an unregistered ID is entered.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Manual tracking-only records can only be created for vehicle IDs found in the vehicle database.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">ConsoleReadyMsgOverride<\/td>\n<td align=\"left\">[Text]<\/td>\n<td align=\"left\">Overrides the standard \u2018READY TO SCAN\u2019 message on the operator console only.<\/p>\n<p>This can be used to display a custom message such as \u2018PRESS \u2018NEW\u2019 TO ADD MANUAL RECORD\u2019 on a stand-alone operator console for manual tracking-only record entry.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">The standard \u2018READY TO SCAN\u2019 message is displayed on the operator console.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-18\"><h3>Miscellaneous<\/h3>\n<p>Additional custom settings that can be enabled as required.<\/p>\n<\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">RequirePreID<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Automatic vehicle identification (RFID tag or LPR) must occur before scanning will start.<\/p>\n<p>&nbsp;<\/p>\n<p>For RFID tag identification this requires cab-mounted tags that can be detected before the truck cab reaches the scan head.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Vehicle pre-identification not required.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">DisableCoverDetection<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-8 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Disable error on detection of cover over the load surface.<\/p>\n<p>Cover detection can be disabled where bin\/load profiles are falsely triggering COVERED\/OVER-FULL errors. This may be caused by:<\/p>\n<ul>\n<li>sudden large drops in front-to-rear load profile<\/li>\n<li>very high loading<\/li>\n<li>very lumpy loads, big rocks, debris.<\/li>\n<\/ul>\n<p>Only suitable for trucks that never have covers fitted, such as mine dumpers.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Cover detection enabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"\">EnableLockoutList<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Vehicles in the vehicle database can be blocked from measuring loads (locked out).<\/p>\n<p>&nbsp;<\/p>\n<p>Reference scan records for locked out vehicles are retained, but the corresponding vehicle IDs are blocked and cannot be used for load measurement.<\/p>\n<p>A \u2018Lock Out\u2019 check-box appears on the Edit Vehicle Record dialog for a vehicle selected in the Vehicle Database screen.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Vehicles cannot be locked out<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"\">ForcePartnerIDPrompt<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Override any permanent pairing between trucks and trailers and force manual prompting for all trailer IDs.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Do not override permanent pairing.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"\">DisableIVP<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\"><strong><i class=\"fb-icon-element-9 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i>\u00a0This setting is ignored on trade certified LVS systems.<\/strong><\/p>\n<p>Disable detection of load generated visual pollution such as steam or dust.<\/p>\n<p>This supresses VISUAL POLLUTION IN TRAY errors but may result in measurement errors where significant amounts of steam or dust are present above the load surface.<\/p>\n<p>Use for lumpy, non-steamy material only.<\/p>\n<p>This is equivalent to setting the \u2018VisPollLevelThresh\u2019 system setting to 0 but gives users the ability to enable and disable detection of load generated visual pollution as and when required.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Load generated visual pollution detection enabled.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"\">TestModeHTMLReport<\/td>\n<td align=\"left\">TRUE<\/td>\n<td align=\"left\">Publish a simple \u2018high-resolution\u2019 HTML scan report for accuracy testing purposes only.<\/p>\n<p>&nbsp;<\/p>\n<p>The HTML report is available at:<\/p>\n<p><em>http:\/\/X.X.X.X\/current.html<\/em><\/p>\n<p>where X.X.X.X is the IP address of the LVS.<\/p>\n<p>Refer to the service-level support document <span style=\"color: #ff0000;\"><em><strong>LoadScan LVS \u2013 Functions and Settings for Trade Certified Systems<\/strong><\/em><\/span> for details.<\/p>\n<p><strong><i class=\"fb-icon-element-10 fb-icon-element fontawesome-icon fa-exclamation-triangle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color7);--awb-font-size:18px;--awb-margin-right:9px;\"><\/i> This setting must not be enabled on trade certified LVS systems, except during accuracy testing.<\/strong><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">FALSE (default)<\/td>\n<td align=\"left\">Test mode HTML report disabled.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-19\"><h2>Region settings<\/h2>\n<p>Region settings control region specific metrological characteristics of the LVS, including parameters for trade legal use in regions where the LVS can be certified for trade use.<\/p>\n<p>This section lists all region settings that can be edited from the system maintenance screen (see <span style=\"color: #ff0000;\"><em><strong>Edit configuration settings<\/strong><\/em><\/span>). These settings can only be viewed or edited with Administrator level access. They should not normally require editing and are listed here for reference only.<\/p>\n<p>General region settings for each region are grouped under section headings corresponding to the region name.<\/p>\n<p>Region settings for trade certified systems are grouped under section headings that have \u2018_Certified\u2019 appended to the region name.<\/p>\n<p>Any settings that are not present in a specific region section use default values.<\/p>\n<\/div><div class=\"fusion-reading-box-container reading-box-container-3\" style=\"--awb-title-color:#333333;--awb-margin-top:20px;--awb-margin-bottom:31px;\"><div class=\"reading-box\" style=\"background-color:#fff4dd;border-width:1px;border-color:#f6f6f6;border-left-width:3px;border-left-color:var(--primary_color);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>Note that all volumetric values are in the specified volume measurement unit and all speed values are in the specified speed unit for the region.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div>\n<div class=\"table-1\" style=\"--awb-margin-top:20px;--awb-margin-bottom:20px;\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\"><strong>Setting Parameter<\/strong><\/th>\n<th align=\"left\"><strong>Value<\/strong><\/th>\n<th align=\"left\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\" align=\"left\">MeasurementUnit<\/td>\n<td align=\"left\">m (default)<\/td>\n<td align=\"left\">Measurements are reported in cubic metres (m<sup>3<\/sup>).<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">yd<\/td>\n<td align=\"left\">Measurements are reported in cubic yards (yd<sup>3<\/sup>).<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">MinCapacity<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The minimum trade legal volume that can be measured\/reported.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">MinTrayCapacity<\/td>\n<td align=\"left\">1.5 (default m<sup>3<\/sup>)<br \/>\n2.0 (default yd<sup>3<\/sup>)<\/td>\n<td align=\"left\">The minimum empty bin capacity below which empty reference scans will be rejected as unsuitable.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range1<\/td>\n<td align=\"left\">999.0 (default)<\/td>\n<td align=\"left\">The maximum value for the first scale range.<\/p>\n<p>This is the maximum capacity per bin if only one scale range is defined.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range1Interval<\/td>\n<td align=\"left\">0.1 (default)<\/td>\n<td align=\"left\">The step size (increment) for the first scale range.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range2<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The maximum value for the second scale range.<\/p>\n<p>This is the maximum capacity per bin if exactly two scale ranges are defined.<\/p>\n<p>No second scale range defined if 0.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range2Interval<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The step size (increment) for the second scale range.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range3<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The maximum value for the third scale range.<\/p>\n<p>This is the maximum capacity per bin if exactly three scale ranges are defined.<\/p>\n<p>No third scale range defined if 0.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Range3Interval<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The step size (increment) for the third scale range.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">OverRangeTolerance<\/td>\n<td align=\"left\">0 (default)<\/td>\n<td align=\"left\">The tolerance margin above the maximum capacity per bin within which a measurement will result in a \u2018LOAD OVER RANGE\u2019 error but the measured volume will still be reported.<\/p>\n<p>Above the tolerance margin a \u2018LOAD OVER RANGE\u2019 error will be reported with no measurement.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">ReportBelowRange<\/td>\n<td align=\"left\">TRUE (default)<\/td>\n<td align=\"left\">If TRUE, measurements below minimum capacity will result in a \u2018LOAD UNDER RANGE\u2019 error and the measured volume will be reported as normal except that it will not show on printed tickets.<\/p>\n<p>If FALSE, measurements below minimum capacity will result in a \u2018LOAD UNDER RANGE\u2019 error with no measurement.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">TicketMessage<\/td>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">An additional text message to be displayed at the bottom of every printed ticket if required.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">ScreenMessage<\/td>\n<td align=\"left\">Blank (default)<\/td>\n<td align=\"left\">An additional text message to be displayed on the LVS operator console screen with every load report if required.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">RefScanExpiryMonths<\/td>\n<td align=\"left\">12 (default)<\/td>\n<td align=\"left\">The period in months after which a reference scan expires and must be updated.<\/p>\n<p>An expired reference scan continues to work but a \u2018REFERENCE SCAN EXPIRED\u2019 warning is reported.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\">SpeedUnit<\/td>\n<td align=\"left\">kph (default)<\/td>\n<td align=\"left\">Minimum and maximum speed limits are defined in kilometres per hour.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">mph<\/td>\n<td align=\"left\">Minimum and maximum speed limits are defined in miles per hour.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">MinSpeed<\/td>\n<td align=\"left\">0.5 (default kph)<\/p>\n<p>0.3 <span style=\"font-family: inherit; font-size: inherit;\">(default mph)<\/span><\/td>\n<td align=\"left\">The minimum vehicle speed during scanning, below which a \u2018TOO SLOW\u2019 error will be generated, and no measurement reported.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">MaxSpeed<\/td>\n<td align=\"left\">8.0 (default kph)<\/p>\n<p>5.0 <span style=\"font-family: inherit; font-size: inherit;\">(default mph)<\/span><\/td>\n<td align=\"left\">The maximum vehicle speed during scanning, above which a \u2018TOO FAST\u2019 error will be generated, and no measurement reported.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1331.2px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-2 sep-underline sep-solid fusion-title-text fusion-title-size-six\" style=\"--awb-margin-top-small:20px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-sep-color:var(--awb-color6);\"><h6 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:18;--minFontSize:18;line-height:1.5;\">Other sections in this Software Servicing Guide<\/h6><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:5.76%;--awb-width-medium:33.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:5.76%;--awb-spacing-left-medium:5.76%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><ul style=\"--awb-size:13px;--awb-iconcolor:var(--awb-color7);--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;\" class=\"fusion-checklist fusion-checklist-1 fusion-checklist-default type-icons\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-arrow-circle-right fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\"><span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/\"><strong>Software Servicing Guide \u2013 Section 1<\/strong><\/a><\/span><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Introduction\">Introduction<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_The_System_Maintenance_screen\">The System Maintenance screen<\/a><\/strong><\/p>\n<ul class=\"awb-toc-el__list awb-toc-el__list--1\">\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Open_the_System_Maintenance_screen\">Open the System Maintenance screen<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Close_the_System_Maintenance_screen\">Close the System Maintenance screen<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_LVS_user_access_to_the_Maintenance_screen\">LVS user access to the Maintenance screen<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Update_LVS_software_manual_mode\">Update LVS software (manual mode)<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Select_LVS_software_update_file\">Select LVS software update file<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-1\/#toc_Update_error_resolution\">Update error resolution<\/a><\/li>\n<\/ul>\n<\/div><\/li><\/ul><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:5.76%;--awb-width-medium:33.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:5.76%;--awb-spacing-left-medium:5.76%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><ul style=\"--awb-size:13px;--awb-iconcolor:var(--awb-color7);--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;\" class=\"fusion-checklist fusion-checklist-2 fusion-checklist-default type-icons\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-arrow-circle-right fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\"><span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/\"><strong>Software Servicing Guide \u2013 Section 2<\/strong><\/a><\/span><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Edit_configuration_settings\">Edit configuration settings<\/a><\/strong><\/p>\n<ul class=\"awb-toc-el__list awb-toc-el__list--1\">\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_System_settings\">System settings<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_User_settings\">User settings<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Custom_settings\">Custom settings<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Region_settings\">Region settings<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Hardware_specific_settings\">Hardware specific settings<\/a><\/li>\n<\/ul>\n<p class=\"awb-toc-el__item-anchor\" style=\"margin-top: 8px;\"><strong><a href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_View_system_log_files\">View system log files<\/a><\/strong><\/p>\n<ul class=\"awb-toc-el__list awb-toc-el__list--1\">\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_TallySync_logs\">TallySync logs<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Mesh_agent_log\">Mesh agent log<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_MyScanner_synchronization_log\">MyScanner synchronization log<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Loadsync_SQL_log\">Loadsync SQL log<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_PostgreSQL_database_logs\">PostgreSQL database logs<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Access_Log\">Access Log<\/a><\/li>\n<\/ul>\n<p class=\"awb-toc-el__item-anchor\" style=\"margin-top: 8px;\"><strong><a href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Reset_remotecontrol_agent\">Reset remote-control agent<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Webbrowser_device_configuration\">Web-browser device configuration<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-2\/#toc_Import_language_file\">Import language file<\/a><\/strong><\/div><\/li><\/ul><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:5.76%;--awb-width-medium:33.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:5.76%;--awb-spacing-left-medium:5.76%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><ul style=\"--awb-size:13px;--awb-iconcolor:var(--awb-color7);--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;\" class=\"fusion-checklist fusion-checklist-3 fusion-checklist-default type-icons\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa-arrow-circle-right fas\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">\n<p><span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/\"><strong>Software Servicing Guide \u2013 Section 3<\/strong><\/a><\/span><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Update_laser_configuration\">Update laser configuration<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Laser_diagnostics_utility\">Laser diagnostics utility<\/a><\/strong><\/p>\n<ul class=\"awb-toc-el__list awb-toc-el__list--1\">\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Determine_scan_area_limits\">Determine scan area limits<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Laser_scan_rate\">Laser scan rate<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Record_scan_profiles\">Record scan profiles<\/a><\/li>\n<\/ul>\n<p class=\"awb-toc-el__item-anchor\" style=\"margin-top: 8px;\"><strong><a href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Serial_port_loopback_test\">Serial port loopback test<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Run_TallySync_debug_mode\">Run TallySync (debug mode)<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Printer_logo_utility\">Printer logo utility<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Export_user_data\">Export user data<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Import_user_data\">Import user data<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Clear_user_data\">Clear user data<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Export_diagnostics_files\">Export diagnostics files<\/a><\/strong><\/p>\n<p><strong><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Manufacturing_tools\">Manufacturing tools<\/a><\/strong><\/p>\n<ul class=\"awb-toc-el__list awb-toc-el__list--1\">\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_Sick_SOPAS\">Sick SOPAS<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_WZP_Sign_Software\">WZP Sign Software<\/a><\/li>\n<li class=\"awb-toc-el__list-item\"><a class=\"awb-toc-el__item-anchor\" href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_pgAdmin_PostgreSQL\">pgAdmin (PostgreSQL)<\/a><\/li>\n<\/ul>\n<p class=\"awb-toc-el__item-anchor\" style=\"margin-top: 8px;\"><strong><a href=\"https:\/\/portal.loadscan.com\/es\/escaner-de-volumen-de-carga-guia-de-mantenimiento-del-software-seccion-3\/#toc_System_configuration_settings\">System configuration settings<\/a><\/strong><\/p>\n<\/div><\/li><\/ul><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Las funciones personalizadas son funcionalidades especiales integradas en el software LVS pero desactivadas por defecto. Las funciones personalizadas espec\u00edficas pueden activarse en los sistemas LVS seg\u00fan sea necesario. Algunas funciones personalizadas se venden como \u00abcomplementos\u00bb de pago.  <\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[205,199,197],"tags":[206],"class_list":["post-17845","post","type-post","status-publish","format-standard","hentry","category-documentos-de-nivel-de-servicio-lvs","category-escaner-de-volumen-de-carga","category-instalacion-y-configuracion-de-lvs","tag-documento-de-nivel-de-servicio"],"_links":{"self":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts\/17845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/comments?post=17845"}],"version-history":[{"count":4,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts\/17845\/revisions"}],"predecessor-version":[{"id":28487,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/posts\/17845\/revisions\/28487"}],"wp:attachment":[{"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/media?parent=17845"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/categories?post=17845"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/portal.loadscan.com\/es\/wp-json\/wp\/v2\/tags?post=17845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}