{"id":30468,"date":"2024-06-10T12:58:06","date_gmt":"2024-06-10T00:58:06","guid":{"rendered":"https:\/\/portal.loadscan.com\/2-configuracao-manual-do-operador-serie-cvs-1-rev3\/"},"modified":"2026-06-19T07:47:53","modified_gmt":"2026-06-18T19:47:53","slug":"2-configuracao-manual-do-operador-serie-cvs-1-rev3","status":"publish","type":"post","link":"https:\/\/portal.loadscan.com\/pt-br\/2-configuracao-manual-do-operador-serie-cvs-1-rev3\/","title":{"rendered":"2 Configura\u00e7\u00e3o &#8211; Manual do Operador &#8211; S\u00e9rie CVS-1 Rev3"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1331.2px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-margin-top-small:20px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h2 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:28;--minFontSize:28;line-height:1.5;\">2. Configura\u00e7\u00e3o<\/h2><\/div><div class=\"fusion-text fusion-text-1\"><h2>2.1 Conecte-se ao CVS<\/h2>\n<p>O CVS possui conectividade de rede sem fio (Wi-Fi) e Ethernet com fio integrada. O m\u00f3dulo de r\u00e1dio sem fio pode ser configurado para usar as bandas de 2,4 GHz ou 5 GHz e suporta os modos hotspot ou cliente.  Ela tamb\u00e9m pode ser desativada. A Ethernet com fio oferece conectividade LAN Gigabit opcional. A conex\u00e3o inicial pode ser sem fio ou com fio e as configura\u00e7\u00f5es de rede podem ser modificadas na interface de usu\u00e1rio CVS.  <\/p>\n<h3>2.1.1 Conex\u00e3o sem fio<\/h3>\n<p>Por padr\u00e3o, o CVS est\u00e1 configurado como um ponto de acesso sem fio com as seguintes configura\u00e7\u00f5es:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Frequ\u00eancia: <\/strong>2,4 GHz<\/div>\n<div style=\"padding-left: 40px;\"><strong>SSID:<\/strong> LoadScan-CVS<\/div>\n<div style=\"padding-left: 40px;\"><strong>Senha:<\/strong> 2BAD4FAB4A<\/div>\n<div style=\"padding-left: 40px;\"><strong>URL do CVS:<\/strong> https:\/\/172.16.1.1<\/div>\n<p>Conecte-se ao ponto de acesso com qualquer dispositivo que tenha Wi-Fi de 2,4 GHz integrado e um navegador da web. Assim que a conex\u00e3o sem fio for estabelecida, a interface do usu\u00e1rio do CVS pode ser aberta em um navegador da web no endere\u00e7o especificado. <\/p>\n<p>A configura\u00e7\u00e3o da rede sem fio pode ser alterada na se\u00e7\u00e3o <strong>\u201cWi-Fi\u201d<\/strong> <strong>da configura\u00e7\u00e3o do sistema<\/strong>, acess\u00edvel pelo menu da interface de usu\u00e1rio do CVS. Conecte-se por Ethernet com fio para alterar a configura\u00e7\u00e3o da rede sem fio. N\u00e3o conecte as interfaces com fio e sem fio na mesma sub-rede.  <\/p>\n<h3>2.1.2 Conex\u00e3o Ethernet com fio<\/h3>\n<p>Por padr\u00e3o, a porta Ethernet com fio (LAN) do CVS est\u00e1 configurada com um endere\u00e7o IP est\u00e1tico da seguinte forma:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Endere\u00e7o IP:<\/strong> 192.168.0.1<\/div>\n<div style=\"padding-left: 40px;\"><strong>M\u00e1scara de sub-rede:<\/strong> 255.255.255.0<\/div>\n<div style=\"padding-left: 40px;\"><strong>URL do CVS:<\/strong> https:\/\/192.168.0.1<\/div>\n<p>Conecte-se por cabo Ethernet a partir de qualquer dispositivo que tenha uma porta Ethernet integrada e um navegador da web. Defina o endere\u00e7o IP do seu dispositivo como um endere\u00e7o IP est\u00e1tico diferente na sub-rede 192.168.0.0. Assim que a conex\u00e3o de rede for estabelecida, a interface do usu\u00e1rio do CVS poder\u00e1 ser aberta em um navegador da web no endere\u00e7o URL especificado.  <\/p>\n<p>A configura\u00e7\u00e3o da Ethernet com fio pode ser alterada na se\u00e7\u00e3o <strong>\u201cEthernet\u201d<\/strong> da <strong>\u201cConfigura\u00e7\u00e3o do sistema\u201d<\/strong>, acess\u00edvel pelo menu da interface de usu\u00e1rio do CVS. Observe que, se um <strong>roteador (gateway)<\/strong> est\u00e1tico ou autom\u00e1tico (DHCP) estiver configurado, a Ethernet com fio ser\u00e1 usada para todas as conex\u00f5es de Rede de Longa Dist\u00e2ncia (WAN); caso contr\u00e1rio, ser\u00e1 usada a conex\u00e3o sem fio. N\u00e3o conecte interfaces com fio e sem fio na mesma sub-rede.  <\/p>\n<h3>2.1.3 Fa\u00e7a login na interface do usu\u00e1rio do CVS<\/h3>\n<p>Quando a interface de usu\u00e1rio do CVS for aberta em um navegador da Web pela primeira vez, ser\u00e1 exibida uma p\u00e1gina de login. Fa\u00e7a login com as seguintes credenciais: <\/p>\n<p style=\"padding-left: 40px;\"><strong>Login:<\/strong> admin<\/p>\n<p style=\"padding-left: 40px;\"><strong>Senha:<\/strong> loadscan<\/p>\n<p>Depois de fazer login como administrador, as op\u00e7\u00f5es de login e as senhas podem ser alteradas na se\u00e7\u00e3o  <strong>Usu\u00e1rios<\/strong>  se\u00e7\u00e3o de  <strong>Configura\u00e7\u00e3o do sistema<\/strong>, acess\u00edvel pelo menu da interface do usu\u00e1rio do CVS.<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\" style=\"--awb-margin-top:40px;\"><h2>2.2 Configura\u00e7\u00e3o do sistema<\/h2>\n<\/div><div class=\"fusion-text fusion-text-3\"><div>As op\u00e7\u00f5es de configura\u00e7\u00e3o est\u00e3o dispon\u00edveis em <strong>\u201cConfigura\u00e7\u00e3o do sistema\u201d<\/strong>, acess\u00edvel pelo menu da interface do usu\u00e1rio do CVS (\u00e9 necess\u00e1rio fazer login como administrador). Use o menu deslizante \u00e0 esquerda para navegar pelas diferentes se\u00e7\u00f5es de configura\u00e7\u00e3o. <\/div>\n<\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1326\" height=\"750\" title=\"CVS-2.2a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a.png\" alt class=\"img-responsive wp-image-30440\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-200x113.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-400x226.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-600x339.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-800x452.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a-1200x679.png 1200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.2a.png 1326w\" sizes=\"(max-width: 800px) 100vw, 1326px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>Por favor, verifique todas as configura\u00e7\u00f5es e ajuste-as de acordo com a sua regi\u00e3o, o seu aplicativo e o seu ambiente de rede. H\u00e1 informa\u00e7\u00f5es adicionais dispon\u00edveis para alguns par\u00e2metros de configura\u00e7\u00e3o ao tocar ou passar o cursor sobre o <i class=\"fb-icon-element-1 fb-icon-element fontawesome-icon fa-info-circle fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:#006fc4;--awb-font-size:14px;--awb-margin-right:7px;\"><\/i> \u00edcone.<\/p>\n<\/div><div class=\"fusion-text fusion-text-5\"><h2>2.3 Configura\u00e7\u00e3o da medi\u00e7\u00e3o<\/h2>\n<\/div><div class=\"fusion-text fusion-text-6\"><div>As configura\u00e7\u00f5es de medi\u00e7\u00e3o est\u00e3o dispon\u00edveis na se\u00e7\u00e3o <strong>Medi\u00e7\u00e3o<\/strong> da <strong>Configura\u00e7\u00e3o do sistema<\/strong>.<\/div>\n<h3>2.3.1 Unidades<\/h3>\n<div>Defina todas as unidades de medida com os valores adequados para a sua regi\u00e3o e aplica\u00e7\u00e3o. As unidades podem ser alteradas a qualquer momento, e todas as medi\u00e7\u00f5es atuais e hist\u00f3ricas exibidas usar\u00e3o as unidades atualizadas. <\/div>\n<h3>2.3.2 Sensibilidade<\/h3>\n<p>A sensibilidade controla a capacidade de resposta da medi\u00e7\u00e3o a n\u00edveis muito baixos de material na correia. Quando definida como Alta (padr\u00e3o), a medi\u00e7\u00e3o \u00e9 acionada pelo n\u00edvel mais baixo detect\u00e1vel de material na correia. Se a vibra\u00e7\u00e3o e o movimento da correia resultarem em medi\u00e7\u00e3o quando a correia estiver vazia, tente alterar a sensibilidade para M\u00e9dia ou Baixa. Isso reduzir\u00e1 as medi\u00e7\u00f5es indesejadas, mas tamb\u00e9m poder\u00e1 resultar em nenhuma medi\u00e7\u00e3o quando a correia estiver levemente carregada. A melhor configura\u00e7\u00e3o deve ser determinada experimentalmente.    <\/p>\n<h3>2.3.3 Velocidade da correia<\/h3>\n<p>Configure o m\u00e9todo de entrada da velocidade da correia e a calibra\u00e7\u00e3o conforme necess\u00e1rio.<br \/>\nSe houver um sensor de velocidade indutivo instalado:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Fonte de velocidade<\/strong> Codificador<\/div>\n<div style=\"padding-left: 40px;\"><strong>Resolu\u00e7\u00e3o do codificador<\/strong> Circunfer\u00eancia do rolo de acionamento em mm, conforme medido em 1.3.2 ou ajuste de modo que a velocidade informada corresponda \u00e0 velocidade conhecida medida com tac\u00f4metro manual ou outro m\u00e9todo.<\/div>\n<p>Observe que a velocidade atual da correia \u00e9 exibida com a m\u00e1xima resolu\u00e7\u00e3o poss\u00edvel na p\u00e1gina \u201cPerfil da correia\u201d, acess\u00edvel pelo menu da interface do usu\u00e1rio. Isso permite uma compara\u00e7\u00e3o precisa da velocidade calibrada da correia. <\/p>\n<p>Se n\u00e3o tiver sido instalado um sensor de velocidade indutivo e a velocidade da correia for um valor constante conhecido:<\/p>\n<div style=\"padding-left: 40px;\"><strong>Fonte de velocidade<\/strong> Velocidade fixa<\/div>\n<div style=\"padding-left: 40px;\"><strong>Velocidade fixa<\/strong> Velocidade conhecida da correia na unidade de medi\u00e7\u00e3o de velocidade selecionada.<\/div>\n<p>Lembra que o valor da velocidade fixa pode ser atualizado por meio da API RESTful HTTP.<\/p>\n<p>Se quiser, defina \u201cUsar sinal de controle de funcionamento da correia\u201d como \u201cSim\u201d para controlar quando a correia est\u00e1 funcionando com um sinal de controle externo. Nesse caso, a velocidade da correia ser\u00e1 for\u00e7ada a zero quando o sinal n\u00e3o estiver ativo. Isso foi pensado para uso com uma configura\u00e7\u00e3o de velocidade fixa, mas funciona com qualquer fonte de velocidade. Uma entrada de comuta\u00e7\u00e3o digital ou bobina Modbus deve ser mapeada para a entrada do sinal de controle \u201cFuncionamento da correia\u201d (veja <em><strong><span style=\"color: #ff0000;\">2.4.1 Atribuir sinais de controle \u00e0s entradas<\/span><\/strong><\/em>).   <\/p>\n<p>Se a velocidade da correia estiver sendo medida por um sistema externo e enviada ao CVS por um cliente Modbus TCP ou por uma entrada de loop de corrente de 4-20 mA (\u00e9 necess\u00e1ria uma caixa CVS-I\/O adicional):<\/p>\n<div style=\"padding-left: 40px;\"><strong>Fonte de velocidade: <\/strong> Entrada de velocidade da correia<\/div>\n<p>Nesse caso, um registro de reten\u00e7\u00e3o Modbus ou um canal de entrada anal\u00f3gica CVS-I\/O deve ser mapeado para a entrada do valor de controle \u201cVelocidade da correia\u201d (veja <em><strong><span style=\"color: #ff0000;\">2.4 Configura\u00e7\u00e3o de Entrada\/Sa\u00edda<\/span><\/strong><\/em><span style=\"color: #ff0000;\">)<\/span>.<\/p>\n<p>Para ativar o c\u00e1lculo da m\u00e9dia da velocidade da esteira, defina o n\u00famero de segundos a ser considerado no campo \u201cPer\u00edodo de c\u00e1lculo da m\u00e9dia da velocidade\u201d. O per\u00edodo m\u00e1ximo de c\u00e1lculo da m\u00e9dia \u00e9 de 600 segundos (10 minutos). Defina o valor zero para desativar o c\u00e1lculo da m\u00e9dia. Observe que o c\u00e1lculo da m\u00e9dia por um longo per\u00edodo pode resultar em atrasos na resposta a mudan\u00e7as repentinas, como a partida\/parada da esteira ou a partida\/parada do material de carga.   <\/p>\n<h3>2.3.4 Taxa de fluxo<\/h3>\n<p>Para ativar o c\u00e1lculo da m\u00e9dia para o volume e a taxa de fluxo de massa, defina o n\u00famero de segundos durante os quais voc\u00ea far\u00e1 a m\u00e9dia em <strong>Per\u00edodo de c\u00e1lculo da m\u00e9dia da taxa de fluxo<\/strong>. O per\u00edodo m\u00e1ximo de c\u00e1lculo da m\u00e9dia \u00e9 de 600 segundos (10 minutos). Defina zero para desativar o c\u00e1lculo da m\u00e9dia. Observe que o c\u00e1lculo da m\u00e9dia durante um longo per\u00edodo de tempo pode resultar em uma resposta atrasada a mudan\u00e7as repentinas, como in\u00edcio\/parada da correia ou in\u00edcio\/parada do material de carga.   <\/p>\n<h3>2.3.5 Altura da carga<\/h3>\n<p>A altura da carga \u00e9 uma medida da altura\/profundidade do material carregado acima da esteira. Defina <strong>o m\u00e9todo de altura da carga<\/strong> como uma das seguintes op\u00e7\u00f5es: <\/p>\n<p><strong>A altura central<\/strong> \u00e9 a altura vertical da carga no centro da esteira.<\/p>\n<p><strong>A altura m\u00e1xima<\/strong> \u00e9 a altura vertical m\u00e1xima da carga. Esse \u00e9 o ponto mais baixo da carga e n\u00e3o necessariamente corresponde ao ponto mais alto da superf\u00edcie superior da carga.<\/p>\n<\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:700px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"900\" height=\"300\" title=\"MPT_CVS-gr\u00e1fico1\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1.png\" alt class=\"img-responsive wp-image-30470\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-200x67.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-400x133.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-600x200.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1-800x267.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph1.png 900w\" sizes=\"(max-width: 800px) 100vw, 900px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-7\"><p>Para ativar o c\u00e1lculo da m\u00e9dia da altura da carga, defina o n\u00famero de segundos durante os quais voc\u00ea far\u00e1 a m\u00e9dia em <strong>Per\u00edodo de c\u00e1lculo da m\u00e9dia da altura da carga<\/strong>. O per\u00edodo m\u00e1ximo de c\u00e1lculo da m\u00e9dia \u00e9 de 600 segundos (10 minutos). Defina zero para desativar o c\u00e1lculo da m\u00e9dia. Observe que o c\u00e1lculo da m\u00e9dia em um longo per\u00edodo de tempo pode resultar em atraso na resposta a mudan\u00e7as repentinas, como in\u00edcio\/parada da correia ou in\u00edcio\/parada do material de carga.   <\/p>\n<h3>2.3.6 Posi\u00e7\u00e3o da carga<\/h3>\n<p>A Posi\u00e7\u00e3o da carga \u00e9 uma medida da distribui\u00e7\u00e3o do material de carga pela correia e informa a posi\u00e7\u00e3o do centro de massa do material de carga, calculada a partir da se\u00e7\u00e3o transversal da carga na correia. A posi\u00e7\u00e3o da carga \u00e9 informada no intervalo de 0 a 1, em que um valor de 0 corresponde \u00e0 extremidade esquerda do perfil zero definido e um valor de 1 corresponde \u00e0 extremidade direita. Um valor de 0,5 corresponde ao centro do perfil zero definido. Se os pontos finais do perfil zero forem sim\u00e9tricos em rela\u00e7\u00e3o \u00e0 linha central do laser, um valor de 0,5 tamb\u00e9m corresponder\u00e1 ao ponto diretamente abaixo do laser.<\/p>\n<\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:400px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"900\" height=\"475\" title=\"MPT_CVS-graph3\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3.png\" alt class=\"img-responsive wp-image-30471\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-200x106.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-400x211.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-600x317.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3-800x422.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/MPT_CVS-graph3.png 900w\" sizes=\"(max-width: 800px) 100vw, 900px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-8\"><p>A posi\u00e7\u00e3o da carga n\u00e3o ser\u00e1 calculada se a altura da carga for menor que <strong>a altura m\u00ednima da carga<\/strong>. Nesse caso, \u00e9 informado o valor 0,5 (centro da correia). <\/p>\n<p>Para ativar a m\u00e9dia da posi\u00e7\u00e3o de carga, defina o n\u00famero de segundos para o c\u00e1lculo <strong>da m\u00e9dia<\/strong> no campo <strong>\u201cPer\u00edodo de m\u00e9dia da posi\u00e7\u00e3o de carga<\/strong>\u201d. O per\u00edodo m\u00e1ximo de m\u00e9dia \u00e9 de 600 segundos (10 minutos). Defina como zero para desativar a m\u00e9dia. Observe que calcular a m\u00e9dia por um longo per\u00edodo pode resultar em uma resposta atrasada a mudan\u00e7as repentinas, como partida\/parada da esteira ou partida\/parada do material de carga.<\/p>\n<\/div><div class=\"fusion-text fusion-text-9\"><h2>2.4 Configura\u00e7\u00e3o de entrada\/sa\u00edda<\/h2>\n<\/div><div class=\"fusion-text fusion-text-10\"><p>O CVS oferece entradas e sa\u00eddas para monitoramento e controle externos por meio do servidor Modbus TCP integrado ou da caixa CVS-I\/O opcional, com entradas e sa\u00eddas anal\u00f3gicas em loop de corrente de 4-20 mA e entradas e sa\u00eddas digitais de comuta\u00e7\u00e3o. Valores de medi\u00e7\u00e3o em tempo real, sinais de status, valores de controle e sinais de controle podem ser mapeados para registros Modbus ou canais de E\/S. <\/p>\n<p>Se a caixa CVS-I\/O estiver instalada, a configura\u00e7\u00e3o <strong>de hardware de E\/S<\/strong> na se\u00e7\u00e3o <strong>Geral<\/strong> da <strong>configura\u00e7\u00e3o do sistema<\/strong> deve ser definida como <strong>CVS External I\/O<\/strong>. As configura\u00e7\u00f5es gerais de entrada e sa\u00edda est\u00e3o dispon\u00edveis na se\u00e7\u00e3o<strong> Entradas\/Sa\u00eddas<\/strong> da <strong>configura\u00e7\u00e3o do sistema<\/strong>. A imagem abaixo mostra apenas um exemplo de configura\u00e7\u00e3o.<\/p>\n<\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"1326\" height=\"1217\" title=\"CVS-2.4a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a.png\" alt class=\"img-responsive wp-image-30441\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-200x184.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-400x367.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-600x551.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-800x734.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a-1200x1101.png 1200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.4a.png 1326w\" sizes=\"(max-width: 800px) 100vw, 1326px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-11\"><h3>2.4.1 Entradas de sinal de controle<\/h3>\n<p>Os seguintes sinais de controle podem ser fornecidos por sistemas de controle externos. Eles podem ser lidos a partir de bobinas Modbus ou de entradas digitais de comuta\u00e7\u00e3o: <\/p>\n<p><strong>Funcionamento da esteira:<\/strong> Se a op\u00e7\u00e3o <strong>\u201cUsar sinal de controle de funcionamento da esteira\u201d<\/strong> estiver marcada na se\u00e7\u00e3o <strong>\u201cVelocidade da esteira\u201d<\/strong> da configura\u00e7\u00e3o <strong>de medi\u00e7\u00e3o<\/strong>, a velocidade da esteira ser\u00e1 for\u00e7ada a zero quando esse sinal n\u00e3o estiver ativo. Isso foi pensado para uso com uma configura\u00e7\u00e3o de velocidade fixa, mas funciona com qualquer fonte de velocidade. <\/p>\n<p><strong>Redefinir totais:<\/strong> uma borda ascendente ou uma transi\u00e7\u00e3o de 0 &gt; 1 nesse sinal vai redefinir os totais acumulados de volume\/massa para zero. Para medi\u00e7\u00f5es no estado inativo, isso tem o mesmo efeito que apertar o bot\u00e3o \u201cRedefinir\u201d no painel. Se um trabalho estiver em execu\u00e7\u00e3o, isso equivale a redefinir o trabalho ativo na p\u00e1gina \u201cTrabalho ativo\u201d.  <\/p>\n<p>Para atribuir um sinal de controle a um canal de entrada, clique no bot\u00e3o <strong>\u201cAdicionar\u201d<\/strong> na se\u00e7\u00e3o <strong>\u201cEntradas de sinal de controle\u201d<\/strong> de <strong>\u201cEntradas\/Sa\u00eddas\u201d<\/strong> e selecione o sinal de controle desejado. Isso cria uma nova linha para o sinal selecionado. Clique na \u00e1rea de mapeamento dessa linha para selecionar um canal de entrada dispon\u00edvel. Um sinal de controle s\u00f3 pode ser mapeado para um canal de entrada.   <\/p>\n<p><strong>Bobinas Modbus:<\/strong> as bobinas precisam ser definidas antes de poderem ser selecionadas como um canal de entrada (veja <em><strong><span style=\"color: #ff0000;\">2.5 Configura\u00e7\u00e3o do servidor Modbus TCP<\/span><\/strong><\/em>).<\/p>\n<p><strong>Entradas digitais de comuta\u00e7\u00e3o:<\/strong> Se o sinal de controle n\u00e3o for do tipo pulso, d\u00e1 pra desmarcar a caixa de sele\u00e7\u00e3o <strong>\u201cAtivo alto\u201d<\/strong> ao adicionar o canal, pra inverter a l\u00f3gica da entrada digital. Essa configura\u00e7\u00e3o pode ser editada a qualquer momento clicando no \u00edcone de configura\u00e7\u00f5es (<i class=\"fb-icon-element-2 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) no canal designado. Consulte <a href=\"https:\/\/portal.loadscan.com\/6-cvs-i-o-installation-guide-operator-manual-cvs-1-series\/\"><em><strong><span style=\"color: #ff0000;\">Guia de Instala\u00e7\u00e3o do LoadScan CVS-I\/O<\/span><\/strong><\/em><\/a> para saber mais sobre os requisitos de sinal e a fia\u00e7\u00e3o.<\/p>\n<\/div><div class=\"fusion-text fusion-text-12\"><h3 id=\"toc_242_Status_signal_outputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.2 Sa\u00eddas de sinal de status<\/h3>\n<p>Os seguintes sinais de status podem ser enviados a sistemas externos de monitoramento e controle ou controlar diretamente a partida\/parada da esteira, ativar luzes indicadoras de status e assim por diante. Eles podem ser gravados em entradas discretas Modbus ou acionar sa\u00eddas de comuta\u00e7\u00e3o digital: <\/p>\n<ul>\n<li><strong>Ocioso:<\/strong> o modo de medi\u00e7\u00e3o est\u00e1 operacional, mas nenhum trabalho est\u00e1 ativo (somente medi\u00e7\u00e3o n\u00e3o atribu\u00edda).<\/li>\n<li><strong>Trabalho ativo:<\/strong> um trabalho est\u00e1 em execu\u00e7\u00e3o. Esse sinal pode ser usado, por exemplo, para ligar a esteira automaticamente quando um trabalho \u00e9 iniciado e para deslig\u00e1-la quando o trabalho \u00e9 interrompido. <\/li>\n<li><strong>Meta da tarefa atingida:<\/strong> o volume\/peso alvo da tarefa ativa foi atingido e a tarefa ainda est\u00e1 em execu\u00e7\u00e3o. Esse sinal pode ser usado, por exemplo, para acionar um indicador visual que avise ao operador que a tarefa est\u00e1 pronta para ser interrompida manualmente. <\/li>\n<li><strong>Correia preta:<\/strong> a correia est\u00e1 funcionando (velocidade da correia maior que zero), mas n\u00e3o h\u00e1 material na correia.<\/li>\n<li><strong>Correia parada:<\/strong> a velocidade da correia \u00e9 zero.<\/li>\n<li><strong>Aviso:<\/strong> condi\u00e7\u00e3o de erro n\u00e3o fatal que requer interven\u00e7\u00e3o do operador est\u00e1 ativa.<\/li>\n<li><strong>Erro:<\/strong> uma condi\u00e7\u00e3o de erro fatal que requer interven\u00e7\u00e3o do operador est\u00e1 ativa (medi\u00e7\u00e3o interrompida).<\/li>\n<\/ul>\n<p>Para atribuir um sinal de status a um canal de sa\u00edda, clica no bot\u00e3o <strong>\u201cAdicionar\u201d<\/strong> na se\u00e7\u00e3o <strong>\u201cSa\u00eddas de status\u201d<\/strong> de <strong>\u201cEntradas\/Sa\u00eddas\u201d<\/strong>e seleciona o sinal de status desejado. Isso cria uma nova linha para o sinal selecionado. Clique na \u00e1rea de mapeamento dessa linha para selecionar um canal de sa\u00edda dispon\u00edvel. Um sinal de status pode ser atribu\u00eddo a v\u00e1rios canais de sa\u00edda. V\u00e1rios sinais de status tamb\u00e9m podem ser atribu\u00eddos a um \u00fanico canal de sa\u00edda. Nesse caso, uma sa\u00edda ficar\u00e1 ativa quando qualquer um dos sinais de status atribu\u00eddos estiver ativado.     <\/p>\n<p><strong>Entradas discretas Modbus:<\/strong> as entradas discretas precisam ser criadas antes de poderem ser selecionadas como um canal de sa\u00edda (veja <em><strong><span style=\"color: #ff0000;\">2.5 Configura\u00e7\u00e3o do servidor Modbus TCP<\/span><\/strong><\/em>).<\/p>\n<p><strong>Sa\u00eddas digitais de comuta\u00e7\u00e3o:<\/strong> A caixa de sele\u00e7\u00e3o \u201cAtivo alto\u201d pode ser desmarcada ao adicionar o canal para inverter a l\u00f3gica da sa\u00edda digital. Essa configura\u00e7\u00e3o pode ser editada a qualquer momento clicando no \u00edcone de configura\u00e7\u00f5es (<i class=\"fb-icon-element-3 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) no canal designado. Consulte <span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/6-cvs-i-o-installation-guide-operator-manual-cvs-1-series\/\"><em><strong>Guia de Instala\u00e7\u00e3o do LoadScan CVS-I\/O<\/strong><\/em><\/a><\/span> para saber mais sobre os requisitos de sinal e a fia\u00e7\u00e3o. <\/p>\n<h3 id=\"toc_243_Control_value_inputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.3 Entradas de valores de controle<\/h3>\n<p>Os seguintes valores de controle podem ser fornecidos por sistemas de controle externos. Eles podem ser lidos a partir de registros de reten\u00e7\u00e3o Modbus ou de entradas anal\u00f3gicas de loop de corrente de 4-20 mA: <\/p>\n<ul>\n<li><strong>Velocidade da correia:<\/strong> Se a fonte de velocidade estiver definida como Entrada de velocidade da correia na se\u00e7\u00e3o Velocidade da correia da Configura\u00e7\u00e3o de medi\u00e7\u00e3o, esse valor definir\u00e1 a velocidade da correia.<\/li>\n<\/ul>\n<p>Para atribuir um valor de controle a um canal de entrada, clique no bot\u00e3o \u201cAdicionar\u201d na se\u00e7\u00e3o \u201cEntradas de valor de controle\u201d de \u201cEntradas\/Sa\u00eddas\u201d e selecione o valor de controle desejado. Isso cria uma nova linha para o valor selecionado. Clique na \u00e1rea de mapeamento dessa linha para selecionar um canal de entrada dispon\u00edvel. Um valor de controle s\u00f3 pode ser atribu\u00eddo a uma sa\u00edda.   <\/p>\n<p><strong>Registros de reten\u00e7\u00e3o Modbus:<\/strong> os registros de reten\u00e7\u00e3o precisam ser criados antes de poderem ser selecionados como um canal de entrada (veja <em><strong><span style=\"color: #ff0000;\">2.5 Configura\u00e7\u00e3o do servidor Modbus TCP<\/span><\/strong><\/em>).<\/p>\n<p><strong>Entradas anal\u00f3gicas:<\/strong> os valores de controle correspondentes aos pontos extremos de 4 mA e 20 mA devem ser definidos no momento em que voc\u00ea adicionar o canal e podem ser editados a qualquer momento clicando no \u00edcone de configura\u00e7\u00f5es (<i class=\"fb-icon-element-4 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) no canal atribu\u00eddo. Consulte <span style=\"color: #ff0000;\"><em><strong><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/6-cvs-i-o-installation-guide-operator-manual-cvs-1-series\/\">Guia de instala\u00e7\u00e3o do LoadScan CVS-I\/O<\/a><\/strong><\/em><\/span> para conhecer os requisitos de sinal de entrada anal\u00f3gica e a fia\u00e7\u00e3o. <\/p>\n<h3 id=\"toc_244_Measurement_value_outputs\" class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 18; line-height: 1.4; --minfontsize: 18;\" data-fontsize=\"18\" data-lineheight=\"25.2px\">2.4.4 Sa\u00eddas de valores de medi\u00e7\u00e3o<\/h3>\n<p>Os seguintes valores de medi\u00e7\u00e3o podem ser enviados para sistemas externos de monitoramento e controle. Eles podem ser gravados em registros de entrada Modbus ou em sa\u00eddas anal\u00f3gicas de loop de corrente de 4-20 mA: <\/p>\n<ul>\n<li><strong>Volume acumulado:<\/strong> o volume total atual<\/li>\n<li><strong>Massa acumulada:<\/strong> o peso total atual<\/li>\n<li><strong>Taxa de fluxo de volume:<\/strong> a taxa de fluxo de volume atual<\/li>\n<li><strong>Taxa de fluxo de massa:<\/strong> a taxa de fluxo de massa atual<\/li>\n<li><strong>Velocidade da correia:<\/strong> a velocidade atual da correia<\/li>\n<li><strong>Altura da carga:<\/strong> a altura da carga atual<\/li>\n<li><strong>Posi\u00e7\u00e3o da carga:<\/strong> a posi\u00e7\u00e3o atual da carga<\/li>\n<\/ul>\n<p>Para atribuir um valor de medi\u00e7\u00e3o a um canal de sa\u00edda, clique no bot\u00e3o <strong>\u201cAdicionar\u201d<\/strong> na se\u00e7\u00e3o <strong>de sa\u00eddas de medi\u00e7\u00e3o<\/strong> da <strong>janela \u201cEntradas\/Sa\u00eddas\u201d<\/strong>e selecione a medi\u00e7\u00e3o desejada. Isso cria uma nova linha para a medi\u00e7\u00e3o selecionada. Clique na \u00e1rea de mapeamento dessa linha para selecionar um canal de sa\u00edda dispon\u00edvel. Um valor de medi\u00e7\u00e3o pode ser enviado para v\u00e1rios canais de sa\u00edda, mas um \u00fanico canal de sa\u00edda s\u00f3 pode ser atribu\u00eddo a uma medi\u00e7\u00e3o.   <\/p>\n<p><strong>Registros de entrada Modbus:<\/strong> os registros de entrada precisam ser criados antes de poderem ser selecionados como um canal de sa\u00edda (veja 2.5 Configura\u00e7\u00e3o do servidor Modbus TCP).<\/p>\n<p><strong>Sa\u00eddas anal\u00f3gicas:<\/strong> os valores de controle correspondentes aos pontos finais de 4 mA e 20 mA devem ser definidos na hora de adicionar o canal e podem ser editados a qualquer momento clicando no \u00edcone de configura\u00e7\u00f5es (<i class=\"fb-icon-element-5 fb-icon-element fontawesome-icon fa-cog fas circle-no fusion-text-flow\" style=\"--awb-iconcolor:var(--awb-color5);--awb-font-size:16px;--awb-margin-right:8px;\"><\/i>) no canal designado. Consulte <em><strong><span style=\"color: #ff0000;\"><a style=\"color: #ff0000;\" href=\"https:\/\/portal.loadscan.com\/6-cvs-i-o-installation-guide-operator-manual-cvs-1-series\/\">Guia de Instala\u00e7\u00e3o do LoadScan CVS-I\/O<\/a><\/span> <\/strong><\/em>para saber os requisitos do sinal de entrada anal\u00f3gica e a fia\u00e7\u00e3o.<\/p>\n<\/div><div class=\"fusion-text fusion-text-13\"><h2>2.5 Configura\u00e7\u00e3o do servidor Modbus TCP<\/h2>\n<\/div><div class=\"fusion-text fusion-text-14\"><p>Os valores de medi\u00e7\u00e3o em tempo real, os sinais de status, os valores de controle e os sinais de controle podem ser mapeados para os registros Modbus. As configura\u00e7\u00f5es do servidor Modbus TCP est\u00e3o dispon\u00edveis na se\u00e7\u00e3o <strong>Servidor Modbus TCP<\/strong> da <strong>Configura\u00e7\u00e3o do sistema<\/strong>. Este documento pressup\u00f5e que o leitor esteja familiarizado com o Modbus TCP. A imagem abaixo mostra apenas um exemplo de configura\u00e7\u00e3o.<\/p>\n<\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:40px;--awb-max-width:900px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"1103\" height=\"1001\" title=\"CVS-2.5a\" src=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a.png\" alt class=\"img-responsive wp-image-30442\" srcset=\"https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-200x182.png 200w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-400x363.png 400w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-600x545.png 600w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a-800x726.png 800w, https:\/\/portal.loadscan.com\/wp-content\/uploads\/2024\/06\/CVS-2.5a.png 1103w\" sizes=\"(max-width: 800px) 100vw, 1103px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-15\"><p>A configura\u00e7\u00e3o do Modbus \u00e9 bem flex\u00edvel. O CVS n\u00e3o tem uma tabela de registros fixa. Os registros Modbus podem ser adicionados e removidos conforme necess\u00e1rio. Os endere\u00e7os dos registros tamb\u00e9m podem ser definidos como voc\u00ea quiser, e h\u00e1 v\u00e1rios formatos de dados dispon\u00edveis.   <\/p>\n<p>O servidor Modbus TCP deve ser ativado com o bot\u00e3o <strong>\u201cAtivar servidor Modbus\u201d<\/strong> e pode ser desativado a qualquer momento sem perder a configura\u00e7\u00e3o atual.<\/p>\n<p>Depois que os registros Modbus forem definidos, eles podem ser usados como canais de entrada ou sa\u00edda e atribu\u00eddos a diferentes valores ou sinais de medi\u00e7\u00e3o ou controle (veja <em><strong><span style=\"color: #ff0000;\">2.4 Configura\u00e7\u00e3o de Entrada\/Sa\u00edda<\/span><\/strong><\/em>).<\/p>\n<p>\u00c9 poss\u00edvel adicionar os seguintes tipos de registros Modbus:<\/p>\n<ul>\n<li><strong>Bobinas:<\/strong> s\u00e3o entradas CVS discretas (sa\u00eddas de um cliente Modbus TCP remoto) e podem ser atribu\u00eddas a entradas de sinal de controle.<\/li>\n<li><strong>Entradas discretas:<\/strong> s\u00e3o sa\u00eddas CVS discretas (entradas para um cliente Modbus TCP remoto) e podem ser atribu\u00eddas a sinais de status.<\/li>\n<li><strong>Registros de reten\u00e7\u00e3o:<\/strong> s\u00e3o entradas de valor para o CVS (sa\u00eddas de um cliente Modbus TCP remoto) e podem ser atribu\u00eddas a valores de controle. H\u00e1 v\u00e1rios formatos de dados dispon\u00edveis, e \u00e9 poss\u00edvel, se quiser, aplicar um divisor ao valor lido de um registro de reten\u00e7\u00e3o. <\/li>\n<li><strong>Registros de entrada:<\/strong> s\u00e3o sa\u00eddas CVS (entradas para um cliente Modbus TCP remoto) e podem ser atribu\u00eddos a valores de medi\u00e7\u00e3o. H\u00e1 v\u00e1rios formatos de dados dispon\u00edveis, e \u00e9 poss\u00edvel, se quiser, aplicar um multiplicador ao valor antes de grav\u00e1-lo em um registro de entrada. <\/li>\n<\/ul>\n<p>Para adicionar um registro Modbus, clique no bot\u00e3o <strong>Add (Adicionar<\/strong> ) do tipo desejado e insira os detalhes solicitados na caixa de di\u00e1logo pop-up. Depois que os objetos Modbus forem criados, eles aparecer\u00e3o automaticamente na se\u00e7\u00e3o <strong>Entrada\/Sa\u00edda<\/strong> da <strong>Configura\u00e7\u00e3o do sistema<\/strong>, com a atribui\u00e7\u00e3o do sinal ou valor selecionado. Um registro Modbus pode ser reatribu\u00eddo a um sinal ou valor diferente ou a atribui\u00e7\u00e3o pode ser removida. A remo\u00e7\u00e3o da atribui\u00e7\u00e3o na configura\u00e7\u00e3o de entrada\/sa\u00edda limpa a atribui\u00e7\u00e3o, mas n\u00e3o remove o registro Modbus da configura\u00e7\u00e3o do servidor Modbus TCP. Ele pode ser removido da configura\u00e7\u00e3o do servidor Modbus TCP ou reatribu\u00eddo na configura\u00e7\u00e3o de entrada\/sa\u00edda.<\/p>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>O CVS possui conectividade de rede sem fio (Wi-Fi) e Ethernet com fio integrada. O m\u00f3dulo de r\u00e1dio sem fio pode ser configurado para usar as bandas de 2,4 GHz ou 5 GHz e suporta os modos hotspot ou cliente. <\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[154,136,148,155],"tags":[],"class_list":["post-30468","post","type-post","status-publish","format-standard","hentry","category-conveyor-volume-scanner","category-cvs-install","category-cvs-operator-manual","category-user-guide"],"_links":{"self":[{"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/posts\/30468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/comments?post=30468"}],"version-history":[{"count":2,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/posts\/30468\/revisions"}],"predecessor-version":[{"id":30536,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/posts\/30468\/revisions\/30536"}],"wp:attachment":[{"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/media?parent=30468"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/categories?post=30468"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/portal.loadscan.com\/pt-br\/wp-json\/wp\/v2\/tags?post=30468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}